INSTRUCTIONS MAGRO-35A
Page 12
SWING GATE OPENER
Note:
1. After the above adjustment the opening or closing is still not reaching the designated
position, is slower than normal, or does not function, the following reason may be
caused:
a. The motor will not wok if the supply voltage is outside operating parameters. Please
confirm the input voltage is 10% of 24 volts
b. Advise to choose above 2.5 square mm with copper wire. It will be better to increase
the wire diameter if long distance wiring.
c. Adjust the motor installed position.
2. In case if you have changed the parameters, make sure to restore factory default
settings before proceed with self-learning procedure.(set D2)
3.
Function Adjustment
(Follow the steps below)
Step 1 : press “f” button ,the indicator will show “c8”
Step 2 : press “+” button, it’ll show in turn
“C9,D0,D1,D2,A1,A2,A3,A4,A5,A6,A7,C0,C1,C2,C3,C4,C5”, PRESS “-“ Button,
it’ll show reversely
Step 3 : press “F” button after choose the item, the indicator will show numbers
Step 4 : press “+” or “_” button to select levels
Step 5 : press “Enter” button to confirm
Step 6 : press “F” button for return to previous configuration menu.
Item
Name / Explanation
Setting
Range
Default
Setting
REM
A0/B0
Intermediate Stop Function with slow speed.
This refers to the sensitivity of gates when
meeting obstacles during slow speed
operation.
0~99
20
Lower setting means
the gates will be more
sensitive to stopping.
A1/B1
Intermediate Stop Function with high speed.
This refers to the sensitivity of gates when
meeting obstacles during high speed
operation.
0~99
50
Higher setting means
the gates are not as
sensitive to stopping on
hitting an obstacle.
A2/B2
Time of opening - slow speed.
Low speed operating time during gate
opening.
0~9.9s
9s
This is the time it takes
to Open/Close the gate
for the Slow Speed part
of the sequence.
A4/B4
Time of closing - slow speed.
Low speed operating time during gate
closing.
0~9.9s
9s