AutoGate VPG2490 Introduction Manual Download Page 9

 

9

 

 

 

In

 

addi on

 

to

 

the

 

entrapment

 

sensor

 

inputs

 

there

 

are

 

opera onal

 

inputs

 

for

 

vehicle

 

detec on,

 

communica on

 

with

 

another

 

gate

 

or

 

similar

 

device

 

as

 

well

 

as

 

push

 

bu ons

 

for

 

control

 

of

 

various

 

modes

 

of

 

opera on.

 

Shadow Loop 

 

While

 

at

 

open

 

limit,

 

hold

 

open,

 

ignore

 

once

 

o

ff 

of

 

the

 

open

 

limit

 

switch.

  

(

Not com-

mon on Ver

Ɵ

cal Pivot Gate)

 

Hold

 

Open

 

FE/Back (Free Exit/ 
Back Away) 

Opens

 

gate

 

as

 

Open1,

 

but

 

when

 

signal

 

is

 

removed,

 

gate

 

is

 

given

 

command

 

to

 

close.

 

(Close

 

command

 

over

 

ridden

 

by

 

any

 

other

 

open

 

or

 

Reverse/Interrupt

 

command

 

or

 

stop

 

command)

 

(Primarily

 

designed

 

to

 

work

 

with

 

FE/Back

 

on

 

Barrier

 

Arms)

 

Starts

 

opening

 

movement

 

from

 

any

 

posi on

 

Close Loop  

Start

 

closing

 

movement

 

from

 

any

 

posi on,

 

Open

 

commands

 

can

 

override.

 

 

If

 

gate

 

is

 

closing

 

when

 

ac vated,

 

gate

 

stops

 

un l

 

clear

 

and

  

then

 

con nues

 

to

 

close

.

 

Close

 

input

 

responds

 

on

 

release

 

of

 

the

 

input

 

normally.

  

Close

 

input

 

will

 

hold

 

the

 

gate

 

open

 

while

 

input

 

is

 

maintained

 

with

 

the

 

gate

 

in

 

the

 

open

 

posi on.

 

When

 

in

 

constant

 

pressure

 

mode,

 

close

 

input

 

responds

 

on

 

ini al

 

press.

 

(

Not

 

com-

mon

 

on

 

Ver cal

 

Pivot

 

Gate)

 

If

 

held

 

in

 

upward

 

mo on,

 

no

 

e

ect.

 

If

 

held

 

in

 

downward

 

mo on,

 

gate

 

movement

 

is

 

paused

 

un l

 

released

 

and

 

con nues

 

downward

 

on

 

release

 

Reverse/Interrupt 

When

 

closing,

 

stops

 

and

 

re-opens.

 

If

 

held,

 

stay

 

open

 

Open / Close PGM 

When

 

menu

 

op on

 

not

 

enabled,

 

Input

 

=

 

open

 

1

 

only.

 

When

 

enabled,

 

input

 

=

 

Open

 

1

 

unless

 

the

 

open

 

limit

 

is

 

reached,

 

it

 

then

 

turns

 

to

 

Close.

 

 

If

 

input

 

is

 

held

 

during

 

OPEN,

 

gate

 

holds

 

open.

  

Input

 

needs

 

to

 

cycle

 

o

ff 

before

 

input

 

can

 

CLOSE

  

gate.

 

If

 

held

 

it

 

remains

 

in

 

its

 

state

 

Open 1 

starts

 

opening

 

movement

 

from

 

any

 

posi on

 

starts

 

opening

 

from

 

any

 

posi on

 

Open 2 

starts

 

opening

 

movement

 

from

 

any

 

posi on

 

Same

 

as

 

above

 

Fire Open 

Absolute

 

open,

 

un l

 

the

 

board

 

is

 

hard

 

power

 

reset,

 

or

 

local

 

reset

 

bu on

 

pushed

 

Locks

 

gate

 

open

 

un l

 

released

 

Stop 

Stops

 

gate

 

at

 

any

 

point

 

and

 

cancels

 

current

 

inputs.

 

Inputs

 

will

 

be

 

ignored

 

un l

 

stop

 

is

 

released.

 

A

 

stop

 

input

 

will

 

disable

 

the

 

auto-close

 

mer

 

If

 

held,

 

no

 

gate

 

movement,

 

inputs

 

ig-

nored.

   

INPUT NAME 

FUNCTION AFTER MOMENTARY TRIGGER 

FUNCTION DURING  

CONTINUOUS TRIGGER 

P2 

Summary of Contents for VPG2490

Page 1: ...1 2490 GENESIS Introduction MODEL VPG2490 FULL SIZE MANUAL AVAIALBLE TO DOWNLOAD AND PRINT AT WWW AUTOGATE COM...

Page 2: ...figura on The new configura on will provide be er control of the gate mo on and will prevent the gate from OVERRUNNING the motor There will be 2 drive configura ons used The standard speed will open o...

Page 3: ...keep the motor moun ng as sembly square either using a tape measure or the notches in the moun ng slides When properly aligned belt tension should be the same in all three belts The GATE drive belt o...

Page 4: ...of the pow er supply The board will s ll control the gate as normal but the motor will run from the ba ery ba eries The on board charging system will now charge the ba eries from the solar panels when...

Page 5: ...e input or an over load of the amp draw on the output The power supplies have a built in overload protec on to prevent damage to itself or the control board If the power supply over heats it will shut...

Page 6: ...it switches P14 Loop Rack Accessory Wiring harness port Used with our LR 3 Loop Rack board J1 USB For data connec on future use P6 Program Plug Used to update board so ware cont P4 P5 Pg 7 8 P1 Pg 6 P...

Page 7: ...24VDC Fused Accessory Power 12VDC Fused Accessory Power SPECIAL NOTE The GENESIS board can be retro fit into older operators If a Genesis board is to be used in non monitored entrapment device gate s...

Page 8: ...at full open un l an INTENDED INPUT is ac vated Keypad Reader Push Bu on Free Exit The close command will close the gate and clear the hold command An Open command or a Reverse command not the Close...

Page 9: ...the open posi on When in constant pressure mode close input responds on ini al press Not com mon on Ver cal Pivot Gate If held in upward mo on no e ect If held in downward mo on gate movement is paus...

Page 10: ...Ac ve for condi ons related to UL325 specifica ons Lock Programmable Selectable Magne c lock op on Ac ve when the gate is closed Solenoid Interlock op on Momentary ac va on to open the bolt that mech...

Page 11: ...o move OPEN Pulse on Motor CLOSE 2 second Pulse when gate starts to CLOSE Hold on Motor OPEN Latches Relay on when gate is OPENING Hold on Motor CLOSE Latches Relay ON when gate is CLOSING P12 P13 AUX...

Page 12: ...e properly set when it leaves the factory If you need to adjust it refer to the instruc ons below If you need to replace contact AutoGate ADJUSTING THE LIMIT POSITION SENSOR 1 In programming mode Set...

Page 13: ...ear and ghtness See page 44 for instruc ons Every 6 months Charge voltage for ba eries should be 27 5 VDC with ba eries disconnected check at ba ery in maintenance menu Every 6 months Check ba ery wat...

Page 14: ...on the GATE DRIVE belts 8 by using a 15 16 wrench This too needs to be fully loosened to allow enough room to remove the belts 7 Remove old belts and install new belts loosely 8 Apply snug pressure to...

Page 15: ...n bolt NOTE Grease fitting must point down Tighten bottom nut NOTE Chain MUST remain level and not twisted once tightened 10 Remove T M pin and restore AC DC power 11 Lowering the gate Initiate the ga...

Page 16: ...ides top bo om of the Slide Assembly Angle 2 Only adjust the nuts 3 to 4 turns 1 4 at a me and check your amperage readings a er each adjustment NOTE your Amps in the OPEN mode should be approximately...

Reviews: