SPRING CHANGING INSTRUCTIONS 

STEPS: 

1.  For ease of access, remove the door and end panel 
nearest the gate. 

2.  Disable the photoelectric sensor/beam if equipped. 

3.  Remove any upper “T” bolts completely and loosen 
the slide assembly screws. 

4.  Loosen the top adjusting nut of the slide assembly.  
Thread the nut up to within four (4”) inches of the top of  
slide mechanism. 

5.  You will now raise the gate.  (

DO NOT 

release the 

disengage lever!)  Initiate the gate to open, immediately 
move to the gate and help raise it open, once the slide 
moves up, hold on the bottom rail of the gate until fully 
open.  The gate may bounce slightly, there will be a loud 
bang but no damage will occur.   

6.  Turn Off AC/DC Power before gate “times out” and 
tries to close. Insert T/M Pin. 

7.  Using a 1 5/16 wrench, loosen and remove the chain 
tension bolt with the damaged spring. 

8.  Replace damaged spring 

9.  Replace chain tension bolt.  

NOTE

: Grease fitting 

must point down!  Tighten bottom nut.  

NOTE

: Chain 

MUST

 remain level and not twisted once tightened. 

10. Remove T/M pin and restore AC/DC power. 

11.  Lowering the gate.  Initiate the gate to close and at 
the same time, assist the gate down by pulling on the      
bottom rail of the gate.  The slide will move down and  
another loud bang as the gate is lowered. 

12.  Turn off AC/DC power. 

13.  Thread the slide nut back down to the slide assem-
bly and tighten. 

14.  Replace the T-Bolts to their original location and 
tighten and tighten the slide assembly screws. 

15.  Restore AC/DC power and hook photoelectric sen-
sor/beam back up. 

16.  Cycle gate. 

 

17.  Spray all springs with a chain lube to prevent corro-
sion. 

18.  Grease Chain Tension bolts, Linkage Arm & Bear-
ings 

RECOMMENDED:  

Always check and adjust the balance  

after any spring change.  Refer to balancing instructions 
at 

www.AutoGate.com 

or the instructions on Page 16 

TOOLS REQUIRED:  

5/16” (Nut Driver), 1/2”, 1 1/8”, 1 5/16” Open End Wrenches 

WARNING: 

 SPRINGS ARE UNDER A TREMENDOUS LOAD.  TAKE EXTREME CAUTION WHEN REMOV-

ING AND REPLACING THEM. 

Summary of Contents for VPG2490

Page 1: ...1 2490 GENESIS Introduction MODEL VPG2490 FULL SIZE MANUAL AVAIALBLE TO DOWNLOAD AND PRINT AT WWW AUTOGATE COM...

Page 2: ...figura on The new configura on will provide be er control of the gate mo on and will prevent the gate from OVERRUNNING the motor There will be 2 drive configura ons used The standard speed will open o...

Page 3: ...keep the motor moun ng as sembly square either using a tape measure or the notches in the moun ng slides When properly aligned belt tension should be the same in all three belts The GATE drive belt o...

Page 4: ...of the pow er supply The board will s ll control the gate as normal but the motor will run from the ba ery ba eries The on board charging system will now charge the ba eries from the solar panels when...

Page 5: ...e input or an over load of the amp draw on the output The power supplies have a built in overload protec on to prevent damage to itself or the control board If the power supply over heats it will shut...

Page 6: ...it switches P14 Loop Rack Accessory Wiring harness port Used with our LR 3 Loop Rack board J1 USB For data connec on future use P6 Program Plug Used to update board so ware cont P4 P5 Pg 7 8 P1 Pg 6 P...

Page 7: ...24VDC Fused Accessory Power 12VDC Fused Accessory Power SPECIAL NOTE The GENESIS board can be retro fit into older operators If a Genesis board is to be used in non monitored entrapment device gate s...

Page 8: ...at full open un l an INTENDED INPUT is ac vated Keypad Reader Push Bu on Free Exit The close command will close the gate and clear the hold command An Open command or a Reverse command not the Close...

Page 9: ...the open posi on When in constant pressure mode close input responds on ini al press Not com mon on Ver cal Pivot Gate If held in upward mo on no e ect If held in downward mo on gate movement is paus...

Page 10: ...Ac ve for condi ons related to UL325 specifica ons Lock Programmable Selectable Magne c lock op on Ac ve when the gate is closed Solenoid Interlock op on Momentary ac va on to open the bolt that mech...

Page 11: ...o move OPEN Pulse on Motor CLOSE 2 second Pulse when gate starts to CLOSE Hold on Motor OPEN Latches Relay on when gate is OPENING Hold on Motor CLOSE Latches Relay ON when gate is CLOSING P12 P13 AUX...

Page 12: ...e properly set when it leaves the factory If you need to adjust it refer to the instruc ons below If you need to replace contact AutoGate ADJUSTING THE LIMIT POSITION SENSOR 1 In programming mode Set...

Page 13: ...ear and ghtness See page 44 for instruc ons Every 6 months Charge voltage for ba eries should be 27 5 VDC with ba eries disconnected check at ba ery in maintenance menu Every 6 months Check ba ery wat...

Page 14: ...on the GATE DRIVE belts 8 by using a 15 16 wrench This too needs to be fully loosened to allow enough room to remove the belts 7 Remove old belts and install new belts loosely 8 Apply snug pressure to...

Page 15: ...n bolt NOTE Grease fitting must point down Tighten bottom nut NOTE Chain MUST remain level and not twisted once tightened 10 Remove T M pin and restore AC DC power 11 Lowering the gate Initiate the ga...

Page 16: ...ides top bo om of the Slide Assembly Angle 2 Only adjust the nuts 3 to 4 turns 1 4 at a me and check your amperage readings a er each adjustment NOTE your Amps in the OPEN mode should be approximately...

Reviews: