background image

 

2

 

VPG2490 OPERATOR

 

The

 

VPG2490

 

is

 

AutoGate’s

 

new

 

UL

 

325

 

Rev

 

7

 

Listed

 

Ver cal

 

Pivot

 

Gate

 

Operator.

 

The

 

VPG2490

 

em-

ploys

 

a

 

90°,

 

(Right

 

Angle

 

Drive)

 

gearmotor,

 

and

 

a

 

newly

 

designed

 

24

 

VDC

 

controller

 

(Genesis

 

Board)

 

and

  

u lizes

 

a

 

new

 

Limit/Posi on

 

Sensor

 

(LPS)

 

to

 

detect

 

gate

 

posi on.

  

The

 

frame

 

for

 

this

 

model

 

is

 

2”

 

taller

 

than

 

the

 

previous

 

model

 

to

 

allow

 

for

 

clearance

 

between

 

the

 

windbracing

 

and

 

the

 

end

 

panel

 

of

 

the

 

operator

 

cab-

inet

 

when

 

the

 

gate

 

is

 

fully

 

open.

   

This

 

allows

 

the

 

addi on

 

of

 

“OPEN

 

EDGE”

 

contact

 

bump

 

strips

 

to

 

be

 

mounted

 

around

 

the

 

gate

 

throat

 

as

 

required

 

by

 

UL

 

325.

   

In

 

addi on

 

to

 

the

 

Gate

 

Throat

 

the

 

en re

 

“Entrapment

 

Area”

 

is

 

required

 

to

 

have

 

“OPEN

 

OBSTRUCTION”

 

protec on

 

per

 

UL

 

325.

 

VPG2490 BELTS

 

The

 

new

 

90°

 

gearmotor

 

is

 

a

 

½

 

horse

 

power

 

motor

 

with

 

a

 

non-back

 

drivable

 

right-angle

 

drive

 

gearbox,

 

and

 

a

 

redesigned

 

sheave

 

and

 

belt

 

con

fi

gura on.

 

The

 

new

 

con

fi

gura on

 

will

 

provide

 

be er

 

control

 

of

 

the

 

gate

 

mo-

on

 

and

 

will

 

prevent

 

the

 

gate

 

from

 

"OVERRUNNING"

 

the

 

motor.

 

There

 

will

 

be

 

2

 

drive

 

con

fi

gura ons

 

used.

 

The

 

standard

 

speed

 

will

 

open

 

or

 

close

 

the

 

gate

 

in

 

8

 

to

 

10

 

seconds,

 

including

 

slowdown.

 

For

 

larger

 

or

 

extra

 

heavy

 

gates

 

the

 

speed

 

will

 

be

 

reduced

 

slightly

 

to

 

prevent

 

excessive

 

wear

 

to

 

the

 

drive

 

mechanism

 

and

 

to

 

allow

 

for

 

safer

 

control

 

of

 

gate

 

mo on.

 

These

 

systems

 

will

 

open

 

or

 

close

 

in

 

13

 

to

 

15

 

seconds,

 

including

 

slow-

down.

 

 

Adjustments

 

to

 

the

 

drive

 

belts

 

are

 

a

 

cri cal

 

part

 

of

 

the

 

gate

 

operator

 

func on.

 

With

 

the

 

introduc on

 

of

 

the

 

½

 

horse

 

power

 

right

 

angle

 

drive

 

gearmotor,

 

the

 

'MOTOR'

 

drive

 

belts

 

have

 

been

 

changed

 

to

 

"A"

 

sec on

 

belts.

 

This

 

now

 

requires

 

3

 

belts

 

to

 

handle

 

the

 

torque.

 

Another

 

reason

 

for

 

the

 

size

 

change

 

from

 

"B"

 

to

 

"A"

 

is

 

it

 

allows

 

us

 

to

 

get

 

be er

 

grip

 

with

 

less

 

belt

 

wear

 

on

 

the

 

small

 

motor

 

drive

 

sheave.

 

The

 

'GATE'

 

drive

 

belts

 

will

 

s ll

 

be

 

the

 

"B"

 

sec on

 

belt.

 

This

 

will

 

con nue

 

to

 

be

 

a

 

"Banded"

 

style

 

belt

 

but

 

will

 

be

 

the

 

"Notched"

 

belt

 

for

 

be er

 

torque

 

and

 

grip.

 

Summary of Contents for VPG2490

Page 1: ...1 2490 GENESIS Introduction MODEL VPG2490 FULL SIZE MANUAL AVAIALBLE TO DOWNLOAD AND PRINT AT WWW AUTOGATE COM...

Page 2: ...figura on The new configura on will provide be er control of the gate mo on and will prevent the gate from OVERRUNNING the motor There will be 2 drive configura ons used The standard speed will open o...

Page 3: ...keep the motor moun ng as sembly square either using a tape measure or the notches in the moun ng slides When properly aligned belt tension should be the same in all three belts The GATE drive belt o...

Page 4: ...of the pow er supply The board will s ll control the gate as normal but the motor will run from the ba ery ba eries The on board charging system will now charge the ba eries from the solar panels when...

Page 5: ...e input or an over load of the amp draw on the output The power supplies have a built in overload protec on to prevent damage to itself or the control board If the power supply over heats it will shut...

Page 6: ...it switches P14 Loop Rack Accessory Wiring harness port Used with our LR 3 Loop Rack board J1 USB For data connec on future use P6 Program Plug Used to update board so ware cont P4 P5 Pg 7 8 P1 Pg 6 P...

Page 7: ...24VDC Fused Accessory Power 12VDC Fused Accessory Power SPECIAL NOTE The GENESIS board can be retro fit into older operators If a Genesis board is to be used in non monitored entrapment device gate s...

Page 8: ...at full open un l an INTENDED INPUT is ac vated Keypad Reader Push Bu on Free Exit The close command will close the gate and clear the hold command An Open command or a Reverse command not the Close...

Page 9: ...the open posi on When in constant pressure mode close input responds on ini al press Not com mon on Ver cal Pivot Gate If held in upward mo on no e ect If held in downward mo on gate movement is paus...

Page 10: ...Ac ve for condi ons related to UL325 specifica ons Lock Programmable Selectable Magne c lock op on Ac ve when the gate is closed Solenoid Interlock op on Momentary ac va on to open the bolt that mech...

Page 11: ...o move OPEN Pulse on Motor CLOSE 2 second Pulse when gate starts to CLOSE Hold on Motor OPEN Latches Relay on when gate is OPENING Hold on Motor CLOSE Latches Relay ON when gate is CLOSING P12 P13 AUX...

Page 12: ...e properly set when it leaves the factory If you need to adjust it refer to the instruc ons below If you need to replace contact AutoGate ADJUSTING THE LIMIT POSITION SENSOR 1 In programming mode Set...

Page 13: ...ear and ghtness See page 44 for instruc ons Every 6 months Charge voltage for ba eries should be 27 5 VDC with ba eries disconnected check at ba ery in maintenance menu Every 6 months Check ba ery wat...

Page 14: ...on the GATE DRIVE belts 8 by using a 15 16 wrench This too needs to be fully loosened to allow enough room to remove the belts 7 Remove old belts and install new belts loosely 8 Apply snug pressure to...

Page 15: ...n bolt NOTE Grease fitting must point down Tighten bottom nut NOTE Chain MUST remain level and not twisted once tightened 10 Remove T M pin and restore AC DC power 11 Lowering the gate Initiate the ga...

Page 16: ...ides top bo om of the Slide Assembly Angle 2 Only adjust the nuts 3 to 4 turns 1 4 at a me and check your amperage readings a er each adjustment NOTE your Amps in the OPEN mode should be approximately...