MONITORED DEVICE CONNECTIONS POINTS
P4 & P5
Monitored Open Edge
When
ac vated,
the
gate
will
stop,
(in
less
than
2
seconds),
and
then
reverse
and
go
to
a
full
close
secured
posi on.
Gate
will
remain
closed
un l
it
receives
an
“INTENDED”
INPUT
(Keypad/Reader/
Push
Bu on/Free
Exit)
or
the
board
is
manually
reset
(Not
from
an
Entrapment
input).
Monitored Open Beam
When
ac vated,
the
gate
will
stop,
(in
less
than
2
seconds),
and
then
reverse
and
go
to
a
full
close
secured
posi on.
Gate
will
remain
closed
un l
it
receives
an
“INTENDED”
INPUT
(Keypad/Reader/
Push
Bu on/Free
Exit)
or
the
board
is
manually
reset
(Not
from
an
Entrapment
input).
Monitored Programmable
Input 1 & 2
Choice
of
Open
or
Close
direc on
by
Menu,
choice
of
Edge
or
Beam
and
then
10K
or
2
wire
by
Menu.
(Refer to PROGRAMMABLE INPUT FUNCTIONAL descrip
Ɵ
ons for required ac
Ɵ
on.
Monitored Close Edge
When
ac vated
the
fi
rst
me,
the
gate
will
stop
in
less
than
2
seconds,
and
reverse
to
full
open
and
allow
the
‘Timer
To
Close’
to
be
ac vated
upon
open
limit.
Upon
the
second
ac va on
closing,
be-
fore
reaching
the
close
limit,
the
gate
will
again
stop,
(in
less
than
2
seconds),
and
reverse
to
full
open
and
the
‘Timer
To
Close’
will
be
deac vated.
The
gate
will
remain
at
full
open
un l
an
“INTENDED”
INPUT
is
ac vated
(Keypad/Reader/Push
Bu on/Free
Exit)
.
The
close
command
will
close
the
gate
and
clear
the
hold
command.
An
‘Open’
command
or
a
“Reverse”
command,
(not
the
Close
Beam
input)
will
trigger
the
reset
of
the
‘Timer
To
Close’
ac va on.
Also,
any
of
the
ac on
bu ons
on
the
control
board
can
ac vate
the
gate,
(Close
bu on
will
close
gate
and
the
Open
&
Stop
bu ons
will
reset
the
‘Timer
To
Close’
to
be
ac ve).
Note:
Upon
the
second
ac va on
before
reaching
the
close
limit,
when
the
gate
is
in
the
“HOLD”
condi on,
any
input
that
was
being
maintained
at
the
me
of
the
second
ac va on
shall
be
ignored
un l
the
gate
is
enabled
by
a
di
ff
erent
input!
If
the
CLOSE
EDGE
remains
ac vated,
no
input
will
re-
lease
the
gate
for
opera on.
Monitored Close Beam
When
ac vated,
the
gate
shall
stop
in
less
than
2
seconds,
and
then
reverse
to
full
open.
The
‘Timer
to
close’
will
become
ac ve
only
a er
all
inputs
are
clear.
UL Alarm
In
the
event
the
gate
receives
sequen al
obstruc ons,
the
UL
Alarm
will
ac vate.
To
clear,
verify
that
there
are
no
obstruc ons
in
the
movement
path
of
the
gate.
Reset
the
gate
by
pressing
the
STOP
bu on
on
the
board
or
pulse
the
STOP
accessory
bu on
input.
If
the
gate
keeps
stopping
with
alarm
ac va on,
check
the
balance,
verify
that
the
OVER
CURRENT
se ng
is
high
enough
to
allow
normal
opera on
of
the
gate.
On
a
2490
system,
make
sure
the
LPS
is
func oning
properly.