• Do not obstruct the gap at the bottom of the heater or
the outlet grille slots.
• Heaters should be switched off while the vehicle is in
motion.
• A guard fitted around the heater is recommended where
children are present.
Note:
Inspect the exhaust duct and all connections at regular
intervals, and always in the event of blow back (misfire).
It is essential for the exhaust duct to be installed so that it
slopes upwards over its whole length and is secured with
several clamps. Never place any object on the exhaust duct,
since this could result in damage.The exhaust duct
connection to both the heater and the cowl must be firm
and well sealed. It is no longer permissible to operate
heaters with incorrectly fitted or damaged exhaust ducts!
Never allow the warm air outlet on the heater to be
obstructed in any way.
For instance never hang washing on or in front of the heater
to dry. Misusing your heater in this way could cause serious
damage from overheating. Do not place flammable objects
near the heater. Please follow these guidelines in the interest
of your own safety.
TRUMATIC C 3402 / C 6002 VEHICLE HEATER
Operating Instructions
Check that any exterior flue covers are removed.
Turn on the gas cylinder and the isolation valve in the
gas supply line.
Summer Operation (Hotwater Only)
Set the rotary switch (c) to summer operation 40°C or
60°C.Once the water temperature has been reached
(40°C or 60°C) the burner will switch off and the yellow
monitor lamp (g) will go out.
Winter Operation
Heating with hot water requirement:
Set the rotary switch (a) to the desired thermostat setting
(1-9). When the system is switched on, the green monitor
light (b) will light up.
Set the rotary switch to the ‘operation’ setting (e).
Depending on the room temperature the heater will
automatically select the output of the heater required.
Once the room temperature has been reached, the burner
switches back to the lowest stage and heats the water
content to 60°C.The yellow monitor lamp (g) indicated the
heating up phase is in progress, and goes out when the
appropriate water temperature has been reached.
Heating without hot water requirement:
Set the rotary switch (a) to the desired thermostat setting
(1-9). When the system is switched on, the green monitor
light (b) will light up.
Set the rotary switch to the ‘operation’ setting (d)
24
7. Gas: Appliances
TRUMATIC C 3402 / C 6002
VEHICLE HEATER
A
- Rotary switch for room temperature
B
- Green ‘operation’ monitor lamp
C
- Summer operation (water
temperature 40
°
C or 60
°
C)
D
-Winter operation (heating without
hot water requirement)
E
- Winter operation (heating with hot
water requirement)
F
- Rotary ‘off’ switch
G
-Yellow ‘boiler heating phase’
monitor lamp
H
- Red ‘fault ‘ monitor lamp
A
G
H
B
C
F
D
E
Final 2006 AT Handbook 1/12/05 12:06 pm Page 24