To view our how to install video visit:
Optional Functions
1.
The Operate interface available
Add another Operate button to open or close the door.
2.
The photo beam interface available
When connecting
pulsed quantity control infrared sensor, wiring as per Fig.12. When infrared sensor is
controlled by switch value, wiring as per Fig.13.
Notice: Close the photo beam function when you
don’t
use
photo beam sensors.
3.
Flash light function (optional)
There are corresponding interfaces for this function and provide 24v-35v flash light voltage. Connect the
flash light with DC 24v-28v,
current≤100mA.
When using flash lights off 220V AC, please match an adapter,
and wiring as required(Fig.14).
4.
Pass door (SD) protection (optional)
This function ensure that the door
can’t
be opened unless the small pass door is closed. The door panel
won’t
be damaged. Connect according to Fig.15 .
Fig. 12