Auto Meter BVA-2100 Instruction Manual Download Page 14

14

14

This gives the user a chance to check the J1708 

connections and obtain pertinent information such as the 

ambient temperature for later use in testing the battery. Keep in mind that the 

ambient temperature may not be the actual temperature of the battery unless 

the vehicle battery has been in the place suffiecient time for the battery to reach 

the surrounding ambient temperature. A low oil temperature would add a greater 

demand on the starter. This information is used by the BVA-2100 to calculate the 

condition of the starter.

Each test throughout the manual does not include the sequence for the J1708 

cable attachment. The only exception is the battery bank test.  Each menu 

sequence will, however, include the following: 

--PM TEST--

>DOES VEHICLE HAVE   
 J1708 DATA PORT?

  'N' OR 'Y'

J1708 DATA (Cont.)

You will be asked if the vehicle 

has a J1708 data port. Answer 

Yes or No.

If you answer yes you will be asked to attach the J1708 cable to the receptacle 

under the dash or on the floor near the drivers seat as illustrated on page 33.

HELP MENU

 STARTER DRAW TEST

 REVIEW/PRINT

 MULTIMETERS

 J1708 DATA

>HELP MENU

 SETUP MENU

 DOWNLOAD

 ABOUT BVA2100

From the main menu SCROLL 

DOWN TO HELP MENU and 

press (Y Enter)

The following help selection will be listed adding valuable information not 

necessarily in manul:

GENERAL INFORMATION

SYSTEM TESTING

BATTERY TESTING

VOLTAGE DROP TESTING

CHARGING CABLES VDROP TESTING

MAG. CIRCUIT VDROP TESTING

GENERIC VDROP TESTING

ALTERNATOR TESTING

STARTER TESTING

REVIEWING AND PRINTING

USING THE MULTIMETERS

J1708 DATA

SETTING UP THE BVA 2100

DOWNLOADING STORED DATA

35

35

 

--BATTERY TEST--

>ENTER BATTERY

 TEMPERATURE    70F.

 

12.39V
  'Y' TO CONTINUE

 

--BATTERY TEST--

>ENTER BATTERY’S 

 RATED CCA   650

 

 12.39V
  'Y' TO CONTINUE

Using the (+) or (-) key adjust the 

temperature in units of 10 degrees. 

This should be the temperature of 

the battery.

Using the (+) or (-) key adjust the 

CCA of the battery. Press (Y Enter) 

to begin test.

Wait for results. 

The tester will prompt to select either LOAD TEST or CAPACITY TEST. Select 

LOAD TEST for batteries that are used for starting application and select 

CAPACITY TEST for batteries that are used for starting and/or extensive 

auxiliary loads. The load test takes 15 seconds to perform and the capacity test 

takes up to 4 minutes and consists of load and rest periods.

There are five test 

results:
GOOD BATTERY

MARGINAL BATTERY

BAD BATTERY

GOOD NEEDS CHARG.

CHARGE AND RETEST

INDIVIDUAL BATTERY TEST (Cont.)

Make sure post 

adapters are 

screwed firmly 

against the lead 

pad.

Use

Post Addapters

 

--BATTERY TEST--

TESTING BATTERY

PLEASE WAIT. . . 

 

--BATTERY TEST--

#220 12V BATTERY

GOOD NEEDS CHRG.

12.28 CHARGE 54%

EST CCA     840

Summary of Contents for BVA-2100

Page 1: ...t measures the voltage drop of the starting and charging circuit The BVA 2100 is automated and menu driven with simple hook up methods for testing the negative and positive legs Special tests are incl...

Page 2: ...ing Fan Load Clamps 10 ft 6 Gauge External Leads 20ft 16 Gauge Size 9 5 X 12 X 13 Post Adapter Kit For group 31 batteries Optional AC 25 6 pin to 9 pin J1708 Adapter Optional AC 26 J1708 Cable Optiona...

Page 3: ...ernator Test Results 19 Using the Amp Probe 20 7 Starting System Test 21 28 8 Magnetic Circuit Test 22 24 9 Starting Cable VDrop Test 25 26 10 Individual Starter DrawTest 27 Starter Test Results 28 11...

Page 4: ...gradually build up and crystallize on the plates greatly reducing the battery s capacity and ability to be recharged n Cycling Excessive drain on battery when alternator is not operating CAUSE OF BAT...

Page 5: ...to the consumer when determined by the manufacturer that the product failed due to defects in material or workmanship This warranty is limited to the repair or replacement of parts and the necessary...

Page 6: ...load in each test Jaw insulation is necessary for accurate readings Damaged clamps or loose wires will affect the readings Keep clamps clean and in good repair DO NOT ATTEMPT TO REPLACE CLAMPS WITH A...

Page 7: ...is 1 0 Volts Maximum drop at 80 Amps is 1 0 Volts Maximum drop at 40 Amps is 2 0 Volts Reports the drops at the entered current Reports the drops at the entered current 24 Volt 12 Volt 24 Volt 12 Vol...

Page 8: ...A to M and 01 00 for the day and the year You have to increment each of these to the desired date that will print out in the standard 00 00 format Select MARGINAL BATTERY to allow the test result to b...

Page 9: ...nsfer Menu then select Stop n Launch Microsoft Excel and select open file n Under Files of Type at the bottom of the open file window select All Files n Highlight your download txt file then select Op...

Page 10: ...PM service NOT when the vehicle is having electrical system issues For a vehicle with a suspected electrical problem use the individual tests starting with the batteries then the cables and finally t...

Page 11: ...al port and you re planning on using Windows HYPER Terminal as illustrated below you will need to buy and install an adapter card with a serial port 11 11 BATTERY BANK TEST 2 You will be asked if the...

Page 12: ...ructed to connect the large leads Connect the red clamp to the main positive cable coming to the bank and the black clamp to the main negative cable leaving the bank Using the or key adjust the CCA of...

Page 13: ...ers on threaded steel posts as illustrated on the next page then press Y Enter When the test results appear as GOOD BATTERIES after running the system battery bank test there is no need to run the ind...

Page 14: ...ng help selection will be listed adding valuable information not necessarily in manul GENERAL INFORMATION SYSTEM TESTING BATTERY TESTING VOLTAGE DROP TESTING CHARGING CABLES VDROP TESTING MAG CIRCUIT...

Page 15: ...test and the alternator test MAIN MENU BATTERY BANK TEST VDROP MENU ALTERNATOR TEST STARTER DRAW TEST REVIEW PRINT MULTIMETERS J1708 DATA J1708 DATA ATTACH J1708 DATA CABLE N TO CANCEL J1708 DATA TURN...

Page 16: ...xternal leads will check the cables before the alternator is tested This is the individual VDorp Test ALTERNATOR HOOKUP Red to Positive Black to Ground BATTERY HOOKUP Black Clamp at Negative Main Red...

Page 17: ...LOADING PLEASE WAIT 27 CHARGE CABLES 01 07 13 11 55AM PASSED AT 120A GOOD UP TO 185A POS DROP 0 18V NEG DROP 0 16V If all connections are correct press y Enter to begin VDrop Test Wait for a load to b...

Page 18: ...nter the alternator rating Press Up or Down key to increment or decrement to the desired test The last 150 tests are held in memory The same tests can be downloaded to a PC See the Download section fo...

Page 19: ...f the cables Both the positive and negative circuit results will be indicated from the single test Select LIFTGATE CHARGE LIFTGATE MOTOR or LIFTGATE TRUCK CIR to perform a voltage drop test on the tra...

Page 20: ...Alternator and the Starter Draw Test whether they are individual tests or within each of the system tests The Amp Probe can also be used in the Multimeters test This section explainsthe proper use of...

Page 21: ...URRENT 640A CRANK TIME 2 24S 218 12V STARTER 07 05 12 05 52PM BEG VOLTS 12 56 END VOLTS 9 48 CURRENT 860A CRANK TIME 1 68S If still out of specifications High Amp reading may indicate engine is out of...

Page 22: ...self The Magnetic switch is energized by the ignition switch in each test For safety disconnect the negative cable from the battery while making the connections INDIVIDUAL MAGNETIC CIRCUIT TEST 8 VDRO...

Page 23: ...ction from the battery press enter and energize the switch again for 3 5 seconds See Illustration small clamp position 2 INDIVIDUAL MAGNETIC CIRCUIT TEST Cont 23 23 MAIN CABLES CONNECT LARGE LEADS TO...

Page 24: ...R Y Does the vehicle have a split battery system This entry is necessary for the tester to calculate 1 2 for each system if selected 9 STARTING SYSTEM VDROP TEST Loose or corroded terminal connections...

Reviews: