User’s Manual – 400E Series
Page 6
Start Engine
The start button can be configured as
latched
or
hold
. It will always be the
same as the stop button, though.
Latched Start
If the button is configured as
latched
,
press the start button, observe the
confirmation dialog, and press the soft
button Start to start.
The DCU will complete the start
sequence.
Hold Start
If the start button is configured as
hold
, press and hold the start button
until the engine has started.
There will be no confirmation dialog.
E-Start
If the DCU is configured for it, an
Emergency Start option is available in
the Start dialog. See the previous
picture.
Note! Activating E-Start will override
any configured Prelube and also set
Shutdown Override. The engine will
start immediately, and run in a
Shutdown Override mode setting.
If necessary, the operator can switch
off Shutdown Override mode once the
engine has started.