User’s Manual – 400E Series
Page 26
Alarm List
Enter the Alarm List
Press the Alarm List button to enter
the alarm list.
Press the Alarm List button again to
leave the alarm list.
The star before the engine name
indicates this RP is the active station
for that engine.
The yellow dot in the Alarm Views
button indicates some filtering is
active.
Silence the Buzzer
If the buzzer sounds, press the alarm
list button to silence the buzzer.
If the alarm list is currently
not
displayed, then this operation
will display the alarm list.
If the alarm list
is
displayed,
pressing the alarm list button to
silence the buzzer will not exit
the alarm list.
Acknowledge a single
alarm
First, select the alarm to be
acknowledged by touching it on
the screen. Note that it will
expand to reveal additional
information, if any.
Press the Acknowledge button
to acknowledge the selected
alarm.
Acknowledge all alarms
In the alarm list, press and hold
(1 sec) the Acknowledge button.
This acknowledges all alarms.
Note! Alarms that are still active will
stay displayed in the screen until they
go inactive. They will have a grey
background.
Active Station indication in
the Alarm List
If a star is displayed just before the
engine name – as in the picture above
– it means this RP is the active station
for that engine.
Note! The RP must be the active
station for a certain engine to be able
to acknowledge alarms on it.
Filter Alarms
The RP can receive alarms from up to
eight different DCU panels.
If alarm filtering is desirable, there are
two buttons for this purpose:
Engine Views (softbutton #2)