background image

3

Australian
Technology

•  Don’t use a gate leaf that exceeds the specified weight, otherwise it will cause failure.

•  If  you  chose  the  electromagnetic  lock,  don‘t  use  it  in  an  environment  beyond  an 

ambient temperature, otherwise it will cause malfunction.

•  The  graphic  drawings  and  specifications  in  this  manul  are  for  reference  only.  You 

should rely upon real objects. Product designes are subject to change without notice .

•  CAUTION!  For  personal  safety,  it  is  important  to  follow  all  the  instructions  carefully. 

Incorrect installation or misuse of the product may cause serious harm to people.

•  Don’t use the gate in a place subject to dampness, vibration or corrosive gas, otherwise 

it may cause accidents such as fire , electric shocks or fall.

•  Make sure that suitable space be available after the gate is opened, otherwise user’s 

fingers may be squeezed by the gate leaf.

•  Don ‘t cut off power when the gate is in operation , otherwise it may result in accident 

to passers-by.

•  Please stick the adhesive sticker on the gate leaf firmly . If not, it may cause injury to the 

passer-by who didn’t pay attention to the gate leaf.

•   Don’t connect an external electric device to the micro controler as it may cause fire .
•  Keep the instructions in a safe place for future reference.
•   This  product  was  designed  and  manufactured  strictly  for  the  use  indicated  in  this 

document. Any other usage not expressly indicated in this Document, may damage 
the product and/or be a source of danger.

•   Do not install the machine in an area subject to explosion hazard. InflammabIe gasses 

or fumes are a serious safety hazard.

•  Before carrying out any work on the system, turn off the electricity supply.
•   Do not make any alterations to the components of the automatic operator.
•  Do not allow children or other people to stand near any moving part of the gate while 

in operation.

•  Keep  transmitters  away  from  children  to  prevent  the  machine  from  being  activated 

accidentally.

•  Disconnect the supply when cleaning or other maintenance is being carried out, if the 

appliance is automatically controlled .

•  The electrical cord plug must plug in ingate outlet or waterproof cover outlet.

Caution

Other Precautions

Summary of Contents for Rotary Arm

Page 1: ...Installation Manual Swing Gate Operator SCISSOR ARM Automatic Entrence Solution Provider ROTARY ARM 24 x 7 Service Support 91 755 00 22 007 91 733 88 52 901 905 DESIGN MANUFACTURE SALES SERVICE...

Page 2: ...nsure the detecting range for the walking area of the gate leaf otherwise the passers by may be collided or squeezed by the gate leaf causing injury Thank you for your purchase of our automatic gate e...

Page 3: ...he adhesive sticker on the gate leaf firmly If not it may cause injury to the passer by who didn t pay attention to the gate leaf Don t connect an external electric device to the micro controler as it...

Page 4: ...Installation Before using the machine check power supply grounding voltage etc Check whether it is connected according to the demand of wiring diagram The gate should be pulled easily and smoothly ma...

Page 5: ...5 Australian Technology Installation dimensions Standard installation layout Motor Control box Transmitters Photocell Optional Alarm lamp Optional...

Page 6: ...6 Australian Technology Fix the Motor s Fix the mounting bracket Fix the straight arm Motor Straight arm M10 x 20 10 Gasket Motor M8 x 160 Mounting bracket M8 nut...

Page 7: ...7 Australian Technology Connect the bending arm Connect the Front Brackt Motor Straight arm M8 nut 8 Gasket Bending arm M8 x 45 Bending arm M8 nut 8 Gasket Front Bracketr Bending arm M8 x 30...

Page 8: ...8 Australian Technology How to release Fix the Front Brackt Gate Motor Relese Bending arm...

Page 9: ...as follow The billowing is a Right motor s limit switch adjustment Before adjusting release the gears and open the gate manually For left motor all direction are contrary Step I Close thc door comple...

Page 10: ...n the door completeIy and confirm which one is the open Limit Block according to the situation then loosen the screw adjustor on Open Limit Block Slep 3 Couple the gears turn on the power adjust more...

Page 11: ...gate which must be the priority of opening one step by step 6 E_ LOCK for electronic lock It can be convected with electronic lock which power is 24VDC 7 Connection of motor for single leaf If the ga...

Page 12: ...12 Australian Technology OPEN FIRST OPEN FIRST...

Page 13: ...ne check power supply grounding voltage etc Check whether it is connected according to the demand of wiring diagram The gate should be pulled easily and smoothly manually when the operator is fitted a...

Page 14: ...14 Australian Technology Standard installation layout...

Page 15: ...15 Australian Technology Installation dimensions Installation...

Page 16: ...16 Australian Technology...

Page 17: ...17 Australian Technology...

Page 18: ...ith step by step PUSH 2 controls single leaf gate which must be the priority of opening one with step by step 6 E_ LOCK for electric lock It can be connected with electric lock which power is 24VAC or...

Page 19: ...19 Australian Technology Right Open First Left Open First...

Page 20: ...20 Australian Technology Meaning of display...

Page 21: ...thorised connection to the Micro Controller will make the Warranty invalid 2 If the installation is not carried out as per Auto Ingress recommended guideline Warranty is void 3 For activation of the o...

Reviews: