18
Australian
Technology
Control Unit
(I) “LIGHT” for a Flash lamp,24VDC.
(2) “MOTOR 1 “, “MOTOR 2” for 2 motors 24VDC.
(3) “LIMIT 1”, “LIMIT 2” for the magnetic limit switch on motor 1, motor 2.
(It is useful only for the motors with magnetic limit switch.)
(4) “PHOTOCELL” for infrared protect device.
(5) “BUTTON”for wall switch. “PUSH 1 “control double-leaf gate with “step-by-step” “PUSH 2”controls single
leaf gate which must be the priority of opening one with “step-by-step”.
(6) “E_ LOCK” for electric lock, It can be connected with electric lock which power is 24VAC or 24VDC.
(7)
Connection of motor for single-leaf :
If the gate is 1 leaf, first, it must be connected with “Motor1”, and
the “dip 2” on “S4” must be OFF.
(8)
Connection of motor for double-leaf :
If the gate is the priority openning leaf must be connected with
“MOTOR1”
, the otherone is connected with “MOTOR2”.
And the “dip2” on “S4” must be “ON”.