8.14.1 Low battery
The Transmitting Unit indicates if the battery is not sufficiently charged.
-
the red LED blinks slowly (one blink per second): the battery has less than 1h run time.
-
The red LED blinks fast: the battery has a 10 minute run time from the first signal, after
which the Transmitting Unit automatically switches off.
It is necessary to bring the Machine to a safe state and replace the battery with a charged
one (see paragraph 8.7).
8.14.2 When the Transmitting Unit is not used
If the Transmitting Unit remains started with no enabled commands, it will automatically
switch off after a predetermined time frame. This time frame is specified in the Technical
Data Sheet (SWITCH-OFF).
Before the Transmitting Unit switches off automatically, the green and red LEDs blink
alternating for 30 seconds.
Activating any actuator corresponding to a movement command reduces the predetermined
automatic switch-off time (SWITCH-OFF) to zero.
Setting or removal of the automatic switch off time (SWITCH-OFF) is done by
Autec and decided by the Machine Manufacturer or by the Installer, depending
on the operation and functions they need on the Machine.
8.15 Switching off the Transmitting Unit
Switch off the Transmitting Unit when not actively using the Radio Remote
Control to operate the Machine, or when work is otherwise interrupted, even
for short periods. Do not leave the load hanging or the Machine in dangerous
conditions (even when charging the Unit or changing the battery).
FAILURE TO DO SO CAN RESULT IN SERIOUS BODILY INJURY OR DEATH
AND/OR PROPERTY DAMAGE.
Voluntary switch off of the Transmitting Unit occurs in the following cases:
-
when the power keyswitch (if present) is turned anti-clockwise or removed;
-
when battery is removed (see paragraph 8.7.2
);
-
when the STOP pushbutton is pressed.