background image

INTEGRATED GUARD UNIT CENTRAL

 

 

 

 

 

17

User Guide 

The automatically generated codes follow a logic sequence: 

 

 

The two first digits correspond to the number of the building (SDL). 

 

The two digits in the middle indicate the plant. 

 

The two last digits represent the flat itself. 

 

Suitable codes of Telephone/Monitor and SDL are assigned to each of the 

automatically generated register. The codes of Telephone/Monitor are generated 
correlatively from “1”, and renew their account for each building (SDL). 

 
The Automatic Entry doesn't generate any content in the fields “Name” and “Flat 

Info”. After the process has finished, it is advisable entering to “Display/Edit” to review 
the generated codes and, if it is desired, edit the registers. When entering to 
“Display/Edit” option, the last generated code will be shown. 
 

4.4.1.3. Erase:

 

 

There are 2 kinds of erasure: 

 

 

Selected Register. 

 

Entire Directory. 

 

Selected Register:

 This option allows navigating through the directory and 

erasing the register shown on the screen. Before erasing the register, the SB will ask for 
confirmation to do it. 

 

Entire Directory:

 This way, all the registers in the directory are erased. In this 

process the switchboard also asks for confirmation before continuing. During the 
process a progress bar will be shown on the screen. 

 

4.4.2. Parameters: 

 

In this menu, the parameters that identify the SB, and those that describe the installation 

of the system, are configured. 

 

 

4.4.2.1. Switchboard:

 

 

The switchboard parameters are 3: 

 

 

ID. 

 

Status. 

 

Manager. 

 

ID:

 Number of identification of the switchboard. It can vary from 0 to 15. 

 

Status: 

It configures the SB as Master or Slave. The Master switchboard defines the 

operating mode of the installation. In other words, all the switchboards will work 
according to their own operating mode, but it is the Master switchboard the one that 
determines if the calls must directly be passed (Direct Mode) or never arrive to the flat 
(Not Disturb Mode). Anyway, if any switchboard takes care of a call and decides to 
make a consult or to pass it, it will be able to do it without any restriction. 

 

Summary of Contents for CENTRAL COMPACT INTEGRADA

Page 1: ...CENTRAL COMPACT INTEGRADA INTEGRATED GUARD UNIT CENTRAL HI 86 02 05 AUX 1 2 3 4 5 6 7 8 9 0 LLAMANDO A 120506 HI 91 12 06 COMPACT COMPACT ENGLISH...

Page 2: ...nillos suministrados 2 Embornar los cables 3 Conectar la central con el latiguillo al circuito del m dulo de conexi n 4 Colgar la central en la plancha fijada en la pared 1 Fix the bracket to the wall...

Page 3: ...chboard powered up Main Features Small size suitable for desk installation Able to manage up to 1024 flats Capability to install more than one SB with communication among then Data load from PC Automa...

Page 4: ...configuration menu see chapter 4 4 To explain the functioning of the switchboard we must differentiate 2 kinds of users On one side the guard porter and on the other side the installer or the owner T...

Page 5: ...ime this button is pressed the Aux2 output of the module of connections is activated for 100 ms activation pulse There is a blue led blue lamp that brings information about the system state because it...

Page 6: ...enter the main menu and then select the Directory option pressing OK Once in the directory keys can be used to navigate across the directory looking for the suitable register When found pressing OK w...

Page 7: ...and it will display this data on the screen If the guard porter doesn t attend the call picking up the handset it will be stored in the queue If the guard porter rejects the call pressing key 1 withou...

Page 8: ...through the directory using or typing a valid call code and then OK Once the correct register is found it is possible to pass the call pressing or perform a consult to the flat with these two function...

Page 9: ...en loaded in the database of the switchboard will be understood as Call to Switchboard On screen the number of the calling panel will be shown and also the identification of Phone Monitor 0 and of SDL...

Page 10: ...the convenience of passing the call through or not So after have talked to the outdoor panel the guard porter contacts with the flat At that moment switchboard and flat have both the same video pictur...

Page 11: ...o 15 To exit this menu the door release key must be pressed To perform the call pick up the handset and press OK The call will be performed in a similar way than if it was a call to a flat Call from Q...

Page 12: ...d directly from the Stand By state pressing key The SB stores up to 25 missing calls These calls can be from flats or switchboards but not from panels Calls are stored according to the order they have...

Page 13: ...ough to the appropriated flat Direct Mode All the incoming calls made from the panels will be automatically passed through to the flats The switchboard will show on screen information about the incomi...

Page 14: ...ones are defined by three parameters Type There are 8 different kinds of ringtones Number of Ringtones Times the ringtone is repeated From 0 mute to 4 Volume There are 3 volume levels The value of the...

Page 15: ...cal arrows advance go back as in the Directory menu but having access to the complete information of each register Unlike the previously explained Directory menu it is not possible to call to the flat...

Page 16: ...the way explained previously Remote Entry With this method the registers are loaded from a PC This way it is possible to load complex directories really fast Before proceeding to load the database of...

Page 17: ...ossible to start up an installation in a very fast and simple way The SB follows this process First of all the SB will ask if it is desired to erase the current directory This is advisable to avoid th...

Page 18: ...the directory and erasing the register shown on the screen Before erasing the register the SB will ask for confirmation to do it Entire Directory This way all the registers in the directory are erase...

Page 19: ...llation These parameters are Pull Up Type Pull Up It can be connected ON or disconnected OFF So that the digital system works it is necessary a Pull Up connected in the line of communications Normally...

Page 20: ...ACCESSES Vo Vi HI 86 02 05 AUX 1 2 3 4 5 6 7 8 9 0 LLAMANDO A 120506 BUS GENERAL ACCESO PRINCIPAL MAIN ACCESS Coaxial Tipo Type RG 59 75 Secciones de hilos Wiring sections Hasta 100 m UP to 100 m Has...

Page 21: ...INTERIOR ACCESSES Vo Vi HI 86 02 05 AUX 1 2 3 4 5 6 7 8 9 0 LLAMANDO A 120506 BUS GENERAL ACCESO PRINCIPAL MAIN ACCESS Coaxial Tipo Type RG 59 75 Secciones de hilos Wiring sections Hasta 100 m UP to 1...

Page 22: ...GRADA ES COMPATIBLE CON LAS SIGUIENTES VERSIONES DE MODULO DE CONTROL 600005 M C DIGITAL 1 4 o POSTERIOR 600006 M C TECLADO 1 8 o POSTERIOR 600007 M C SDL 1 5 o POSTERIOR 730121 SDL 1 1 o POSTERIOR 60...

Reviews: