english
50
Polly
6 Troubleshooting
The control panel conveys messages and warnings for alarms and errors that occur while using the
control unit. The display symbols indicate a problem. In case of an alarm, the symbols blink; in case of
errors, the symbols remain continuously illuminated. In the event of an alarm, the fire chamber is still
capable of functioning; in the event of an error, there is a severe functional malfunction of the fire
chamber and the service personnel must be informed.
Every alarm and error is assigned a code with which the problem can be identified. To display the code,
keep the Cancel key pressed. If no alarm/error code is available, "----" will be shown on the display.
Display Code
Cause
Solutions
A001
Low fuel level
Refill fuel level
----
No fuel
Refill fuel level
A003
Combustion chamber or flue is dirty
Check and empty the combustion chamber,
have the flue swept
A004
Battery is weak
Replace battery
See Item 5. Replacing the battery
----
Air quantity sensor is dirty
Remove air quantity sensor and blow away
dirt from measurement sensor
Air quantity sensor is defective
Replace air quantity sensor
----
The door combustion chamber door
is open,
the ash box is not in place,
grate does not close
Close the door to the combustion chamber,
put in ash box,
check for pellets between grate and burner
bowl, grate motor
E109
Tank lid not completely closed,
grate cannot close
Remove possibly stuck pellets
E001
Control panel error
Take note of the error code and contact the
service personnel
E004
Mainboard communications error
E101
Excessive temperature in the
combustion chamber
E107
Flame temperature sensor error
(TC2)
E108
Safety temperature delimiter error
E109
Tank lid pressure switch error
E110
Room sensor error (NTC1)
E112
Combustion chamber sensor excess
temperature
E115
General error
To acknowledge the error message, keep the ON/OFF key pressed until the symbol no longer lights up.
6.1 LED display on the control unit
The control unit has two LED displays that provide information on the control unit operation. The LED
signals are described in the table below:
Signal
LED 2
LED 1
Function
Checking the power supply
Checking the communication
OFF
No power supply
Malfunction or not programmed
Illuminates
Power supply OK
–
Blinks rapidly
(5 times per second)
–
Communication OK
englisch
Summary of Contents for Polly light
Page 1: ...Polly Benutzerhandbuch manuel d instructions Istruzioni per l uso user instructions...
Page 2: ......
Page 8: ...deutsch 6 Polly 4 2 Men struktur Abbildung 2 Men struktur deutsch...
Page 21: ...Polly 19 fran ais 4 2 Structure du menu Image 5 structure du menu fran ais...
Page 34: ...italiano 32 Polly 4 2 Configurazione del menu Figura 8 Configurazione del menu italiano...
Page 47: ...Polly 45 english 4 2 Menu structure Figure 11 Menu structure englisch...
Page 67: ......