Vetec SPM24
ENGLISH
8
BLUSPM24
8.
Storage and transportation
In order to protect the battery powered press tool BLUSPM24 from possible damage it is ne-
cessary to clean it after every usage. After operation stow away the tool in the provided cotton
bag and make sure it is securely closed.
and can cause situation of danger.
Caution:
Th e typical A-weighted noise level can exceed 70dB (A) during the working pro-
cess. - wear ear protection!
A
Caution:
Th e equipment may be operated only with the original BLUCHER
power packs.
A
Caution:
Th e equipment must not be operated in explosive atmospheres.
A
Caution:
Complete shutdown of the equipment takes place exclusively upon removal of
the battery.
A
Caution:
If oil leaks from the press tool, it must be sent to the BLUCHER
customer service
department.
A
Caution:
Th e press tool must not be operated in case of heavy rain or underwater.
A
Caution:
Hydraulic oils are dangerous for ground water. Uncontrolled loss or disposal of
hydraulic oils not in conformity with norms may be persecuted under environmental pro-
tection laws.
A
Caution:
It must be demonstrated that the applied components withstand the tempera-
tures that occur.
9.
Start up of the equipment
Insert the battery and push until the safety switch clicks as shown in the
illustration.
For safety reasons, the battery shall only then be inserted, when a corres-
ponding pressing jaw is installed.
Th e press tool mustn´t be operated without a pressing jaw.
SPM24
The equipment may be operated only with the original power packs.
If oil leaks from the press tool, it must be sent to an authorised customer service
In order to protect the battery powered press tool SPM24 from possible damage it is necessary
to clean it after every usage. After operation stow away the tool in the provided case/bag and
make sure it is securely closed.