17. What to do in case of breakdown
In case of failure the crimping/cutting tool is shut down automatically and remains blocked.
Th e service LED illuminates red or orange. Further process is only possible by changing the
battery or respectivly removing it for a short time.
If the failure of the crimping/cutting tool continues after „reset“, contact the BLUCHER
custo-
mer service.
17.1 Error codes Service
Failure
Cause / trouble shooting
after crimping/cutting process
green light
Operating data OK
green/red fl ashing
Operating data OK and service interval exceeded / service
needed
red fl ashing
Operating data
marginal
/ please contact service center
red light
Operating data
false
service needed
orange light
Temperature failure / tool has to be heated up or cooled
down
after inserting the battery
green ligth
No failure
orange light
Temperature failure / tool has to be heated up or cooled
down
17.2 Error codes battery
Failure
Cause / trouble shooting
after crimping/cutting process
off
No malfunction
red fl ashing
Charge/change battery (approx. 10% capacity)
red light
Battery fl at
after inserting the battery
green light
No malfunction
red light
Charge/change battery
17.3 Error codes battery charger
17.3 Error codes battery charger
SPM24
In case of failure the crimping/cutting tool is shut down automatically and remains blocked.
Th e service LED illuminates red or orange. Further process is only possible by changing the
battery or respectivly removing it for a short time.
If the failure of the crimping/cutting tool continues after “reset“, contact an authorised
customer service department.