50
FAULT
DESCRIPTION
LCD Digits Description
ACTION
Anomaly as parasitic
flame, APT failure
or APS failure
Desired
flame level
is shown
·
Yellow LED permanently OFF
·
Green and LED blink slowly and simultaneously
Turn off main power to the fireplace for 30 minutes.
Ignition Lockout
“A1”
·
Yellow LED permanently OFF
·
Red LED permanently ON
·
Green LED performs 1 blink followed by a 1s
pause
Check for gas presence. Reset and retry ignition
sequence. If problem persists, contact a qualified
service person
High water level
fault
“A2”
·
Yellow LED permanently OFF
·
Red LED permanently ON
·
Green LED performs 2 blinks followed by a 1s
pause
Contact a qualified service person
Transducer fault
“A3”
·
Yellow LED permanently OFF
·
Red LED permanently ON
·
Green LED performs 3 blinks followed by a 1s
pause
Check air pressure switch and air pressure
transducer hose connections. Reset fireplace and try
ignition. If problem persists, contact a qualified
service person
Pressure switch fault
“A4”
·
Yellow LED permanently OFF
·
Red LED permanently ON
·
Green LED performs 4 blinks followed by a 1s
pause
Check air pressure switch and air pressure
transducer hose connections. Reset fireplace and try
ignition. If problem persists, contact a qualified
service person
Overheat lock-out
“A5”
·
Yellow LED permanently OFF
·
Red LED permanently ON
·
Green LED performs 5 blinks followed by a 1s
pause
Allow fireplace to cool completely then reset
fireplace. If problem persists, contact a qualified
service person
Thermistor fault
“A6”
·
Yellow LED permanently OFF
·
Red LED permanently ON
·
Green LED performs 6 blinks followed by a 1s
pause
Contact a qualified service person
Inadequate Combus-
tion Airflow
“A7”
·
Yellow LED permanently OFF
·
Red LED permanently ON
·
Green LED performs 7 blinks followed by a 3s
pause
Contact a qualified service person
Thermistor temp too
high
“A0”
·
Yellow LED permanently OFF
·
Red LED permanently ON
·
Green LED performs 1 blink followed by a 3s
pause
Allow fireplace to cool completely then reset
fireplace. If problem persists, contact a qualified
service person
TROUBLESHOOTING LCD FAULT CODES ON THE DISPLAY PANEL
Operation
LCG DIGITS
CONTROL BOARD LED SEQUENCE
Power on
sequence
Blank
·
Yellow LED permanently OFF
·
Green and Red LED blink four times alternatively
Standby
“—”
·
Yellow LED permanently OFF
·
Red LED permanently OFF
·
Green LED blink slowly and continuously
Operation Safety
Check
Desired flame level is shown
·
Yellow LED on at pressure threshold check
·
Green and red LED’s blink rapidly and alternately
Heat Request
Desired flame level is shown
·
Yellow LED permanently OFF
·
Red LED permanently OFF
·
Green LED blinking fast and continuously
TROUBLESHOOTING LCD CODES—NORMAL OPERATION