FLUEING REQUIREMENTS
Co-Axial Flue Installations
Note: This appliance has been approved for co-axial flue application. If the flue (as
supplied by the manufacturer) is installed to an external wall or external fireplace.
(Refer installation diagrams for Co-Axial Flue Installations on the following pages)
Single Flexi Installations
Note: This appliance has been approved for single flue pipe installation. If the unit and flue
pipe is installed in line with the manufacturer‘s installation instructions.
(Refer installation diagram for single flue pipe installations on the following pages)
MAXIMUM AND MINIMUM FLUE CONFIGURATIONS
Max Horizontal Balanced Flue
Ø40mm/65mm Co-ax pipe
6.1m Length
No 90° or 45° degree bends
Min Horizontal Balanced Flue
Ø40mm/65mm Co-ax pipe
0.45m Length
No 90° or 45° degree bends
Not for connection to Vertical Balanced Flue
Max Vertical Single Flue
Ø40mm pipe x 5.1m total length incorporating 1m length of Ø50mm flexi pipe
1 x 90° bend
2 x 45° bends
Min Vertical Single Flue
Ø40mm pipe x 3.1m Length incorporating 1m length of Ø50mm flexi pipe
1 x 90° bend
2 x 45° bends
Max Horizontal Single Flue
Ø40mm pipe x 1.5m total length incorporating 1m length of Ø50mm flexi pipe
1 x 90° bend
Min Horizontal Single Flue
Ø40mm pipe x 0.45m Length
INSTALLATION INSTRUCTIONS