DIDO Jr. Installation Manual
28
11 Firmware update
The internal software of DIDO Jr. (the firmware) can be updated. This is necessary since new FW will
correct bugs from previous versions or add new functionalities. The serial port of the DIDO Jr. must be
connected to the RS-232 (“COM”) port of a PC-compatible personal computer, running MS-Windows 98,
2000, or XP operating systems. Make certain to set the baud rate to 115k, unit address to 0, and back up
the settings before updating firmware. Always check the serial number on the DIDO Jr. unit to make sure
the new firmware is compatible with the hardware revision. Some features may not work depending on
DIDO Jr. model, which is determined by the four digit batch number (example: bbbb-SNxxxx with
“bbbb” representing the batch number).
Update procedure
•
Create a directory for the DIDO Jr. (such as C:\DIDO).
•
Save the attached files to the created directory.
•
Unzip the files if necessary.
•
Open a Win32 (Command Prompt) window (Start
Æ
Run
Æ
cmd
Æ
Enter).
•
Change to DIDO Jr. directory (C:\DIDO).
•
Type this command “DIDOldr.exe 1 DIDO.did” and press “Enter.” (Note: To change the COM
port use the appropriate comm. port number in place of the 1)
•
It will take approximately 20 seconds to finish programming and the device will restart itself. If
it does not restart, unplug the power and re-apply it after 5 seconds.
•
Under System Settings select Default Settings and confirm.
Important: avoid programming the DIDO Jr. using USB-RS232 adapter since it may not work
properly.
Example:
“DIDOldr.exe 1 DIDOJr.did”
DIDO.ldr.exe: program loader
1: COM port used to program the DIDO Jr. (for example, 2 is for COM 2)
DIDOJr.did: firmware (this file name can be anything such as DIDOJr040916.did)
Microsoft Windows XP [Version 5.1.2600]
(C) Copyright 1985-2001 Microsoft Corp.
C:\DIDO >DIDOldr.exe 1 DIDOJr.did
DIDO Jr. firmware loader V2.03 Copyright (c) 2003 Aurora Multimedia
Loading "DIDOJr.did"
Opening Com 1... OK
Initiating bootblock..... OK
Initiating load procedure... OK
Transferring image header... OK
Waiting for header response... OK
Erasing flash... OK
Loading flash image (137674 bytes)... 100% OK
Rebooting device...
Warning:
In the event the firmware update is interrupted during the transfer process, cycle the power on the DIDO
Jr. and wait 30 sec after reapplying the power to start the transfer process again. The LCD screen may be
blank but that is normal if this should happen.