6.3
RF characteristics
Parameter
Conditions
Notes
Symbol
Min
Typ
Max
Unit
General RF conditions
Operating frequency
fop
2400
2484
MHz
Modulation
mod
FSK
Data rate
HS 1.5
1,2
DR1
1.2
1.5
2
kbps
HS 3
1,2
DR2
2
3
4
kbps
HS 6
1,2
DR3
4
6
8
kbps
HS 12
1,2
DR4
8
12
16
kbps
NS 24
1,2
DR5
24
kbps
NS 48
1,2
DR6
48
kbps
NS 72
1,2
DR7
72
kbps
Channel spacing
F
CHW
4
MHz
Transmitter Operation
RF Output power on UFL
connector
(
RTX-24EM-HP-AE/H and RTX-
24EM-HP-AE/V versions)
See note 4
3,4
P
RFMAX
+20
dBm
See note 4
3,4
P
RFEU
+10
dBm
E.R.P. RF power
(
RTX-24EM-HP-AI/H and RTX-
24EM-HP-AI/V versions)
See note 4
3,4
P
ERPMAX
+18
dBm
See note 4
3,4
P
ERPEU
+9
dBm
Receiver Operation
Sensitivity
HS 1.5
1
S
HS1.5
-119
dBm
HS 3
1
S
HS3
-117
dBm
HS 6
1
S
HS6
-115
dBm
HS 12
1
S
HS12
-111
dBm
NS 24
1
S
NS24
-104
dBm
NS 48
1
S
NS48
-102
dBm
NS 72
1
S
NS72
-101
dBm
Table 5: RF characteristics
Note 1
: HS = High Sensitivity , NS = Normal Sensitivity.
Note 2
: Data rate “on air”. In case of more than 4 consecutive identical symbols, bit stuffing can reduce this
data rate from 100% down to 80% of this value.
Note 3
: to be in compliance with European standard EN 300 440, the maximum radiated power is +10dBm.
Note 4
: See Table 10 for more detailed power amplifier settings
.