Dimensions of fixtures are approximate and may vary ± 6mm (1/4”). Structure measurements must be verified against the unit to ensure proper fit.
Product images and specifications are for illustrative purposes only, product design may vary.
Installation Manual
ASR1202-OO *** Valve Rough-In
5
1
2
3
1
2
3
Test the Handle/Valve:
Water temperature will decrease when you rotate
clockwise, and water temperature will increase when you
rotate counter clockwise.
CLEANING STOP FILTERS
Removing the stop filters:
Using a wrench, take out both of the
Stops (1)
by rotating
them counter-clockwise.
Remove
Filter (2)
and
Valve (3)
and check for any debris
or build up.
Use clean water to rinse and clean
Filter (2)
.
Installing the stop filters:
Slide
Filter (2)
on to
Valve (3)
. Then thread it to the valve
body.
Use a wrench to tighten the
Stops (1)
to the valve.
3A.
4A.
4B.
Thermostatic Valve Cover Plate and Handle Installation
)
Tempature Lock;
must be pushed.
3A.
4A.
4B.
CAUTION!
If you need to adjust temperature more
than 38°C (100°F), then you need to press
the override button and rotate it counter
clockwise. It should not be possible to turn
the stem further counter-clockwise.
REQUIRED
REQUIRED
Testing Handles and Replacing and Cleaning Stop Filters
Installing Cover Plate:
Carefully install the
Trim Plate (1)
, make sure to keep the
Trim Plate (1)
tight against the wall.
Configuring the Cartridge:
Before installing the handle and the rest of the trim,
ensure the thermo cartridge is positioned correctly. Verify
that the line etched on the top of the
Plastic Body (1)
of
the cartridge lines up exactly with the black line on the
brass
Boarch (2)
as you are looking down on it.
(See Figures D2. and D3. on the left)
Installing Volume Control Handle:
Install
Plastic Washer (4)
on diverter. Install the
Volume
Control Handle (1)
. Use the
Allen Key (9)
to tighten the
Handle Set Screw (3)
, then insert
Set Screw Cap (3)
.
Installing Thermostatic Handle:
Install
Plastic Washer (5)
on the thermostatic mixer.
Install the
Thermostatic Mixer Handle (6)
, so that the
safety stop override button is at the 9:00 position. Use
the
Allen Key (9)
tighten the
Handle Set Screw (8)
, then
insert
Set Screw Cap (7)
.
2C.
2D.
2E.
Thermo Cartridge Calibration Area
D2.
D3.
CAUTION!
Please check that the marked line on
the thermostatic cartridge points to the
rectangle notch on the plastic parts, if not,
please rotate the brass part. Then install
the handle.
Marked Line & Groove
MUST ALIGN
1
2
1
2
3
6
9
4
10
5
11
8
7
1
2C.
2D.
TOP VIEW
(1)
(2)
Plastic Body
Boarch