![AUMA SG 04.2 Operation Instructions Manual Download Page 33](http://html1.mh-extra.com/html/auma/sg-04-2/sg-04-2_operation-instructions-manual_3016497033.webp)
Motor speed
Speed LOCAL
Speed REMOTE
Speed I/O interface
Description of parameters:
Speed LOCAL
Output speed for operation via local controls (operation mode Local); Setting range:
linear between 0 – 100 % of max. motor speed; Default value = 50.0 %
Speed REMOTE
Output speed in operation mode Remote for setting the parameter
Speed I/O interface
=
Internal
; Setting range: linear between 0 – 100 % (0 % = min. motor speed, 100
% = max. motor speed); Default value = 50.0 %
Speed I/O interface
=
External
In operation mode Remote, the output speed is defined via analogue input AIN 1 (4
– 20 mA).
=
Internal
In operation mode Remote, the output speed is not defined via analogue input AIN
1 but via the
Speed REMOTE
software parameter.
Table 11:
Beispielwerte zur Einstellung für Baugrößen SG 04.2/05.2/07.2
Operating time
Output drive
[s]
Speed
Motor
[rpm]
Output speed via
AIN1
(
Speed I/O interface
=
External
)
Output speed via parameter:
Speed LOCAL
Speed REMOTE
4 – 20 mA
52
133
4.0
0.0 %
22
314
5.4
9.0 %
16
431
6.3
14.0 %
11
627
7.7
23.0 %
8
863
9.5
34.0 %
5.6
1,232
12.3
52.0 %
4
1,725
16.0
75.0 %
3.1
2,250
20.0
100.0 %
Table 12:
Example values for SG 10.2 size setting
Operating time
Output drive
[s]
Speed
Motor
[rpm]
Output speed via AIN1
(
Speed I/O interface
=
External
)
Output speed via parameter:
Speed LOCAL
Speed REMOTE
4 – 20 mA
81
133
4.0
0.0 %
32
338
5.5
10.0 %
22
491
6.7
17.0 %
16
675
8.1
26.0 %
11
928
10.4
40.0 %
8
1,350
13.2
57.0 %
5.6
1,929
17.6
85.0 %
4.8
2,250
20.0
100.0 %
33
SG 04.2 – SG 10.2
with actuator controls MEC 03.1
Basic settings for the actuator controls