The following table provides an overview of the different positions indications and
refers to the chapter describing the respective setting.
Table 9: Position indications
Page
Indication range
Figure
page 29, Position indication for 90°
90°
page 30, Position indication for 120°
120°
page 30, Position indication for 45° – 360°
45° – 360°
7.3.1.
Position indication for 90°
Figure 23: Position indicator
1.
Remove screw plug [1].
2.
Operate actuator to end position CLOSED.
3.
Turn inner shaft [2] using a suitable screwdriver until the display windows of
position indicator [3] are red.
4.
Operate actuator to end position OPEN.
5.
Check whether the windows of the position indicator [3] are completely green.
➥
If yes: Position indicator has been correctly set. If no: Resume as of step 1.
29
PF-Q80 – PF-Q600
Commissioning