Commissioning the System
Repeaters
64
Engl
ish
Requirements:
– Handsets set up for the use of repeaters
– Handset registered with base station
– Handset within range of the base station and the repeater
1.
First, disconnect the repeater you want to register from its power supply, if necessary. Insert
the RJ-45 plug of the power plug of a disconnected repeater into the socket provided on the
back of the repeater, if necessary.
2.
To switch a repeater into registration mode, insert the power plug and unplug it again within
1-5 seconds.
3.
Re-insert the power plug of this repeater back into its socket.
Note:The LED on the repeater will indicate the registration mode by blinking slowly.
You have five minutes now to register the repeater with the base.
4.
Press and hold the Paging key on the base station for about 10 seconds.
The Paging key will start to blink.
5.
Release the Paging key on the base station.
After a short waiting period, the LED on the repeater will blink fast and without interruption.
6.
Press the call control button on the handset.
The repeater's LED now stays lit.
7.
Using the keypad on the handset, enter the desired RPN. The following entries are possible:
The LED on the repeater will blink based on the selected digit.
Note: Every RPN can be used only once.