INSTALLER
HIGH-TEMPERATURE ENERGY EFFICIENT HEAT PUMP
MANUAL
-
37
6.5.2 - Accessing calculated data
hp input
43
.
5
°
C
hp output
52
.
6
°
C
EVAPO
6
.
2
°
C
compres
- -
1
97
.
0
°
C
compres
- -
2
87
.
0
°
C
Pilot
40
.
0
°
C
PRESSure
0.7
Dhw temp
53
.
0
°
C
heat curv1
62
.
0
°
C
air hp
6
.
2
°
C
Temperature of water
returning to Heat Pump
Temperature of water leaving
from Heat Pump
Outdoor air temperature
measured by Heat Pump
Evaporator
temperature (part
of Heat Pump)
Temperature of compressor 1
discharge
Temperature of compressor 2
discharge
Temperature of water leaving
from HRC
70
Pilot
Pressure in heating circuit (in
bars)
Temperature of DHW tank
Target temperature at Heat
Pump inlet (where there is
only one circuit)
example
example
example
example
example
example
example
example
example
example
shedding
2
AQUASTAT
0
swim. pool
23
.
5
°
C
flow
0
Pt / opt
0
Load shedding status (
0
= load
shedding in progress,
1
= no
load shedding)
Circuit 2 DHW aquastat (no
heating request =
0
, heating
request =
1
)
Swimming pool circuit water
temperature
Load shedding status for peak
and off -peak times (
0
= load
shedding in progress,
1
= no
load shedding)
example
example
example
example
data calc.
Accessing the Installer Menu:
• Press
• Turn the dial until the screen displays
"INST. MENU"
• Press
and
at the same time
•
Keep them held down simultaneously
for 3 sec.