INSTALLER
HIGH-TEMPERATURE ENERGY EFFICIENT HEAT PUMP
MANUAL
-
5
1.2 - Safety instructions and advice
• The Heat Pump must only be installed outdoors.
• This appliance is not intended for use by people (including
children) who have reduced physical, sensory or mental
capacities, or by people who have insuffi
cient experience or
knowledge of the product, unless they are being supervised by
someone who is responsible for their safety and in possession of
the instructions on how the appliance should be used.
• Installing the Heat Pump indoors is
strictly forbidden
.
• The Heat Pump has an operating range of -20°C to 40°C. When
the temperature falls below -20°C, the installation is no longer
heated by the Heat Pump, but by the back-up.
• It is FORBIDDEN :
- to let the Heat Pump run using air intake which contains
solvents or explosive matter
- to use air intake which contains grease, dust or aerosol
particles
- to connect vented exhaust hoods
• It is
FORBIDDEN
to use the appliances if the installation is not
fi lled with water
• All work undertaken on the installation must be carried out by
a qualifi ed professional with the appliances disconnected from
the mains power supply.
• This appliance must be installed in accordance with national
electrical installation regulations.
• Check that the installation is equipped with a properly sized and
connected ground cable.
This CE-approved unit is in compliance with the essential
requirements of the following directives:
- low voltage 2006/95/CEE (standard EN 60.335.1)
- electromagnetic compatability 2004/108/CEE (standard EN
55014.1 / EN 55014.2).
• Any work undertaken on the refrigerant circuit must be carried
out by a qualifi ed professional with a category 1 certifi cate
of aptitude. It is prohibited to release refrigerant into the
atmosphere: it is mandatory to recover the refrigerant before
beginning any work on the circuit.
The Heat Pump uses type R290 refrigerant. Given the fl ammable
nature of this fl uid, any work done on the refrigerant circuit must
be carried out using the correct equipment and in compliance
with all current regulations. In case of handling the fl uid (recovery,
evacuation or refi lling), the machine must be switched off . Do not
smoke or light any fl ame ( e.g. lighter, blowtorch) when handling the
fl uid. If any work needs to be undertaken on the refrigerant circuit
using a fl ame (e.g. a blowtorch) the refrigerant must be evacuated
fi rst and replaced with nitrogen.
1.3 - Delivery terms and conditions
In general, the material is transported at the recipient’s own risk.
It is essential to check that all the elements have been received
and that no damage has been sustained during transport upon
receipt of the appliance and before beginning the installation
procedure.
Heat Pump
Accessories
Pilot
1.4 - Storage and transport
Acceptable transport temperatures are from -20°C to +60°C.
1.4.1 - General information
1.4.2 - Transporting with a forklift truck
1.4.3 - Transporting manually
The appliances must be stored and transported in their packaging
on a wooden pallet and completely empty of water.
When being transported by a forklift truck, the Heat Pump must
remain upright on a wooden pallet.
When moving the Heat Pump do not lift or lower the unit suddenly
as it can easily lose its balance. It should also be suitably secured to
prevent it from tipping over.
The Heat Pump can be manually transported using 2 26mmØ bars
or by putting straps through the holes provided.
Ø 26mm
bar
Do not damage
the heat exchanger
fi ns during handling or
transport.
Heat Pumps
should never be
laid on their sides. Do not
tilt the appliance more
than 30°