16
3.2.4
Errors warning list (heating control)
In case of heating behavior failure, the alarm system activates flashing visualizations on the display
(see pict. h), stopping in the meantime the thermo regulator.
Suspend immediately the sealing operations
(if the machine is working in automatic mode, the sealing jaws are executing the sealing cycle, yet )
Switch off the machine and try to solve following the help list below.
pict. h
3.2.5
alarm message list
N° ERROR
CAUSE
ACTION
E-1
EEPROM failure
contact AUDION Service Dept.
E-2
a) cool join failure
b) machine temperature overheating due
environmental temp.
a) replace the thermo regulator
b) place the machine in an ambient where the
temperature corresponds to the par. 1.4
characteristic
E-4
EEPROM wrong parameters
do new software configuration
replace the thermoreg. if new data lost occurs
E-5
a) temp. probe on failure
b) temp. probe disconnected
a) replace with new one
b) check the probe electrical wires connection
or the probe mechanical fitting in the jaws