37
a
utomatIon
I
ntegratIon
MAESTRO M9
Command Structure - Receiving
Command processing begins when the first 0x0D (carriage return) is re-
ceived. The Maestro M9 will respond, either by making the change speci-
fied with a status update answer code or by replying with an error answer
code, within 3 seconds. More commands, however, may be sent before the
Maestro M9 responds to the first command. When a command is received,
the Maestro M9 echoes the command back in the following format:
<ST><ZN><CC><AC><DL><Data><ETR>
Parameter
Command
Description
s
tArt
0x21
Begins transmission to
Maestro M9
Z
one
n
umber
0x01
Zone 1
0x02
Zone 2
C
ommAnD
C
oDe
See code list
The code of
the command
A
nswer
C
oDe
0x00
No problems – status
updated
0x82
Incorrect Zone
0x83
Incorrect Command
0x84
Incorrect Parameter
0x85
Invalid Command in
current state
0x86
Data length is
incorrect
D
AtA
l
ength
0x01, 0x02 etc…
Number of data units
to follow
D
AtA
See code list
The parameters for the
response, limited to
255
ETR
0x0D
End transmission
As an example:
Answer code for source change in Zone 1 to DVD: 0x21 0x01 0x0A 0x00
0x01 0x00 0x0D