CHAPTER 5 Cabling the Device
MP-1288 | Hardware Installation Manual
Figure 5-16: Cabling FXS Lifeline
Connecting the Serial Interface to a Computer
The RS-232 interface port is used to access the command line interface ( CLI) for serial
communication.
The device provides an RS-232 serial interface port on its rear panel. The RS-232 interface port
is used to access the device's command line interface (CLI).
■
Port Type: RJ-45
■
Cable: RJ-45 to DB-9 female cable adapter (supplied)
Figure 5-17: RJ-45 to DB-9 Female Cable Adapter
■
Connector Pinouts:
Table 5-4: RJ-45 to DB-9 Serial Cable Connector Pinouts
RJ-45
DB-9 Female
Pin
Signal
Pin
Signal
1
Internally used
8
Not
used
2
Ground (GND)
6
Ground
(GND)
3
Transmit Data (TXD)
2
Receive
Data
(RXD)
4
Internally used
5
Not