Installation & Maintenance Manual
5. OSN Platform
Version 6.8
33
Microsoft Lync Server
5.2.2 LED Description
The OSN3 module LEDs are shown in the figure below and described in the subsequent
table.
Figure
5-4: OSN3 Module LEDs
Table
5-6: OSN3 Module LEDs Description
Item
Label
Color
State
Description
1
Green
Flashing Hardware normal operation.
Red
On
Hardware fault (over-temperature or excess
voltage feed).
2
3
Red
On
When lit during boot-up, indicates power failure.
Flashing Processor over-temperature above 100°C. If LEDs
0, 1, and 2 are also flashing, there is a processor
over-temperature above 125°C and as a result,
the module shuts down.
-
Off
Normal operation.
3
2
Red
On
When lit during boot-up, indicates clock failure.
Flashing Chipset over-temperature above 105°C. If LEDs 0,
1, and 3 are also flashing, there is a processor
over-temperature above 125°C and as a result,
the module shuts down.
-
Off
Normal operation.
4
1
Red
On
When lit during boot-up, indicates a hardware
reset.
Flashing Processor over-temperature above 125°C and as
a result, OSN3 shuts down (if LEDs 0, 2, and 3
are also flashing)
-
Off
Normal operation.
5
0
Red
On
When lit up during boot-up, indicates a BIOS boot
failure.
Flashing Processor over-temperature above 125°C and as
a result, OSN3 shuts down (if LEDs 1, 2, and 3
are also flashing)
-
Off
Normal operation.
Summary of Contents for Mediant 1000B SBA
Page 2: ......
Page 22: ......
Page 38: ......
Page 54: ......
Page 70: ......
Page 142: ......
Page 191: ...Part VI Upgrading the SBA Components This part describes how to upgrade the SBA components...
Page 192: ......
Page 204: ......
Page 233: ...4 Part VIII Appendices...
Page 234: ......
Page 298: ...SBA Installation and Maintenance Manual www audiocodes com www audiocodes com...