88
58
Troubleshooting
• If the CX
iR
receiver is being used with an HX2000
hand-held transmitter then this is not a fault as the
HX2000 transmitter does not send a battery condition
signal.
• Check that you are monitoring the transmitter that
was supplied with the receiver. Due to the unique
way in which the low transmitter battery signal is
transmitted, the system is factory set as a matched
pair, and therefore if the transmitters and receivers
are mixed this could result in an incorrect indication.
Fault: Switching indicators for RX1, RX2 staying on
one side
• Check the antennae on the receiver.
Fault: No audio
• Check that the No Signal indicator is off.
• Check that the transmitter gain position switch is set
correctly, in the range 0-7 for an electret/dynamic
microphone and 8-9 for the line-level input.
• Check the microphone on the transmitter.
• Check the output cable.
• Check the mixer/recorder settings.
Fault: Noise on audio
• Check that the input and output cable connectors are
latched in position.
• Check for a break or loose connection on the
microphone cable.
• Check the output cable.
§ 8 Troubleshooting
12/10/01, 3:20 pm
58