VSS-401-x Installation and Operation Manual
Document # 540335, Rev IR, 10/2006
Page 19 of 21
5.0
Instructions for Continued Airworthiness
5.1 Airworthiness
Limitations
No
periodic scheduled maintenance or calibration is required for continued
airworthiness of the VSS-401-x.
If the unit fails to perform to
specifications, it must be removed and serviced by a qualified service
facility.
5.2 General Troubleshooting Procedures
•
Verify power to the unit by rech28 VDC power is applied to the
proper pins on the unit. Use a voltmeter to verify correct level.
•
Remove power from the unit for at least one (1) minute and reapply
power.
•
Recheck all connections to the unit for security. Check all harness
runs for possible pinching. Recheck all pinouts for application
accuracy.
6.0 Specifications
Physical Specifications – VSS-401-x
Weight
Approx. 0.6 lb / 0.27 kg
Dimensions
(l x w x h)
5.0" x 3.08" x 1.05"
12.7 cm x 7.82 cm x 2.67 cm