![Audio Design Associates CINEMA REFERENCE Mach II Installation Manual Download Page 112](http://html1.mh-extra.com/html/audio-design-associates/cinema-reference-mach-ii/cinema-reference-mach-ii_installation-manual_3008130112.webp)
Page 111
RESERVED
FF,03,00,10,85,98,FF
*reserved for this application
RESERVED
FF,03,00,10,86,99,FF
*reserved for this application
RESERVED
FF,03,00,10,87,9A,FF
*reserved for this application
RESERVED
FF,03,00,10,88,9B,FF
*reserved for this application
RESERVED
FF,03,00,10,89,9C,FF
*reserved for this application
RESERVED
FF,03,00,10,8A,9D,FF
*reserved for this application
RESERVED
FF,03,00,10,8B,9E,FF
*reserved for this application
RESERVED
FF,03,00,10,8C,9F,FF
*reserved for this application
RESERVED
FF,03,00,10,8D,A0,FF
*reserved for this application
RESERVED
FF,03,00,10,8E,A1,FF
*reserved for this application
RESERVED
FF,03,00,10,8F,A2,FF
*reserved for this application
record - Select record 1
FF,03,00,10,90,A3,FF
record - Select record 2
FF,03,00,10,91,A4,FF
record - Select record 3
FF,03,00,10,92,A5,FF
record - Select record 4
FF,03,00,10,93,A6,FF
record - Select record 5
FF,03,00,10,94,A7,FF
record - Select record 6
FF,03,00,10,95,A8,FF
record - Select record 7
FF,03,00,10,96,A9,FF
record - Select record 8
FF,03,00,10,97,AA,FF
record - Select record 9
FF,03,00,10,98,AB,FF
record - Select record 10
FF,03,00,10,99,AC,FF
record - Select record 11
FF,03,00,10,9A,AD,FF
record - Select record 12
FF,03,00,10,9B,AE,FF
record - Select record 13
FF,03,00,10,9C,AF,FF
record - Select record 14
FF,03,00,10,9D,B0,FF
record - Select record 15
FF,03,00,10,9E,B1,FF
record - Select record 16
FF,03,00,10,9F,B2,FF
record - Select record 17
FF,03,00,10,A0,B3,FF
record - Select record 18
FF,03,00,10,A1,B4,FF
record - Select record 19
FF,03,00,10,A2,B5,FF
record - Select record 20
FF,03,00,10,A3,B6,FF
update - record
FF,03,00,10,A4,B7,FF
RESERVED
*all below are reserved for this application
DSP CINEMA MODE COMMANDS 3 (commands are ignored if system is in quad mode)
vol - master-up direct (step 1)
FF,03,ADDRESS,11,VOLUME,FF
If step 2 if not sent in less than
100ms command is cancelled
vol - master-dn direct (step 2)
FF,03,ADDRESS,12,VOLUME,FF
GLOBAL COMMANDS 1 (card address is ignored. unit address is not ignored)
RESERVED
*all above are reserved for this application
n u l l
FF,03,ADDRESS,03,05,FF
update - send all possible information
FF,03,ADDRESS,03,06,FF
update - card version
FF,03,ADDRESS,03,07,FF
all zones mute & off followed by a system power off
FF,03,ADDRESS,03,08,FF
DC voltage is absent within all zones
system power off
FF,03,ADDRESS,03,09,FF
DC voltage is absent within all zones
system power on
FF,03,ADDRESS,03,0A,FF
DC voltage is present within all zones
RESERVED
*all below are reserved for this application
GLOBAL COMMANDS 2 (card address is ignored. unit address is ignored)
RESERVED
*all above are reserved for this application
n u l l
FF,03,ADDRESS,04,05,FF
update - send all possible information
FF,03,ADDRESS,04,06,FF
update - card version
FF,03,ADDRESS,04,07,FF
all zones mute followed by a system power off
FF,03,ADDRESS,04,08,FF
DC voltage is absent within all
possible zones
system power off
FF,03,ADDRESS,04,09,FF
DC voltage is absent within all
possible zones
system power on
FF,03,ADDRESS,04,0A,FF
DC voltage is present within all
possible zones
RESERVED
*all below are reserved for this application