17
2) The zones which you want to control with the selected wall panel can be selected by means of the
“Controlled zones” dropdown list. When selecting a zone in this dropdown list, the zone name will
appear in the listbox below. The zones can be removed again from this listbox by selecting them, and
clicking the “Remove Zone” button.
3) The inputs which are selectable with the selected wall panel can be selected by means of the
“Selectable inputs” dropdown list. All inputs which available on the R2 can be selected in this drop-
down list, such as the direct line inputs, the peripheral inputs, the fiber inputs, the priority inputs and
the integrated DSP signals. When selecting an input signal in this list, the signal name will appear in
listbox below. The input signals can be removed again from this listbox by selecting them, and click-
ing the “Remove Input” button. A maximum of 24 signal inputs can be selected. The inputs which are
selected in this listbox, are available for all zones which can be controlled by this DW5065 wall panel.
Those inputs are not linked with the quick menu like the inputs on the DW3018/4018 are.
4) Certain actions such as Volume change, Input change, Mute change, Tone control change and set-
tings change can be blocked by checking the checkboxes.
Summary of Contents for DW5065