Aube Technologies TH146-P-DE Installation Manual Download Page 9

TH146-P-DE 

      400-280-004-C                    11/29/06                    9/9

Manual Adjustment

In manual adjustment, the humidity level is set by the user (5% to
60%).

n

Press the 

Hum

 button until 

MAN

 appears on the screen.

o

Press one of the 

 buttons to adjust the humidity level.

p

Press the   button to return to normal display.

Automatic Adjustment

In automatic adjustment, the humidity level is set by the controller
based on the outdoor temperature to prevent ice formation or con-
densation on the windows while providing enough humidity for your
comfort. However, the user can apply an offset (-9% to 9%). For
example, the user can enter a negative offset if there is still ice for-
mation or condensation on the windows.

n

Press the 

Hum

 button until 

AUTO

 appears on the screen. The 

current humidity level set by the controller is also displayed. 

o

Press one of the 

 buttons to place or modify the offset.

p

Press the   button to save and exit the programming.

Off

To turn off the humidity control:

n

Press the 

Hum

 button until 

OFF

 appears on the screen.

o

Press the   button to save and exit the programming.

CT280-HP-2H1C Control Module

Power supply

: 24 VAC 

Current consumption

: 150 mA

Maximum load per output

: 1 A @ 24 VAC

Short cycle protection

: 2 minutes

Control cycles

: 2 to 6 per hour

Operating temperature

: 0°C to 50°C (32°F to 122°F)

Storage temperature

: -20°C to 50°C (-4°F to 122°F)

Humidity conditions

: 0% to 95%, non-condensing

Dimensions

: 76 mm x 109 mm x 25 mm (3 in. x 4.3 in. x 1 in.)

TH146-P Console

Temperature setpoint range
Heating mode

: 5°C to 30°C (40°F to 86°F)

Cooling mode

: 15°C to 40°C (59°F to 104°F)

Humidity setpoint range

: 5% to 60%

Indoor temperature display range

: 0°C to 70°C (32°F to 158°F)

Outdoor temp. display range

: -50°C to 70°C (-58°F to 158°F)

Temperature display resolution

: 0.5°C (1°F)

Program protection

: non-volatile memory

Operating temperature

: 0°C to 50°C (32°F to 122°F)

Storage temperature

: -20°C to 50°C (-4°F to 122°F)

Humidity conditions

: 0% to 95%, non-condensing 

Dimensions

: 79 mm x 79 mm x 24 mm (3.1 in. x 3.1 in. x 1 in.)

Aube warrants this product, excluding battery, to be free from
defects in the workmanship or materials, under normal use and ser-

vice, for a period of three (3) years from the date of purchase by the
consumer. If at any time during the warranty period the product is
determined to be defective or malfunctions, Aube shall repair or
replace it (at Aube's option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to

the place from which you purchased it, or 

(ii) contact Aube. Aube will make the determination whether the

product should be returned, or whether a replacement product
can be sent to you.

This warranty does not cover removal or reinstallation costs. This
warranty shall not apply if it is shown by Aube that the defect or mal-
function was caused by damage which occurred while the product
was in the possession of a consumer.
Aube's sole responsibility shall be to repair or replace the product
within the terms stated above. AUBE SHALL NOT BE LIABLE FOR
ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCI-
DENTAL OR CONSEQUENTIAL DAMAGES RESULTING,
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR-
RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF
THIS PRODUCT. Some provinces and states do not allow the
exclusion or limitation of incidental or consequential damages, so
this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE
MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED
WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANT-
ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS
HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS
WARRANTY. Some provinces and states do not allow limitations on
how long an implied warranty lasts, so the above limitation may not
apply to you.
This warranty gives you specific legal rights, and you may have
other rights which vary by province or state.

If you have any questions about the product installation or opera-
tion, or concerning the warranty, contact us at the address shown
below.

For more information on our products, visit us at:

www.aubetech.com

7.2

Humidity Adjustment

8. Technical Specifications

9. Warranty

10.Support

705 Montrichard 
Saint-Jean-sur-Richelieu, Quebec 
J2X 5K8
Canada
Tel: (450) 358-4600
Toll-free: 1-800-831-AUBE
Fax: (450) 358-4650
Email: [email protected]

10, rue Ampère
95500 Gonesse
France
Tel: 33 (0) 1 34 07 99 00
Fax: 33 (0) 1 34 07 99 19
Email: [email protected]

As an E

NERGY

 S

TAR

® partner, Aube Technologies 

has determined that this product meets the 

E

NERGY

 S

TAR

 guidelines for energy efficiency.

Summary of Contents for TH146-P-DE

Page 1: ...or air outlet or stagnant air behind a door Do not install the console on a wall hiding air ducts nor expose it to direct sunlight NOTE If this controller replaces an existing thermostat the wires tha...

Page 2: ...oller terminals PS and CS no polarity For more information refer to the instructions provided with the sen sor NOTE The maximum wire length is 30 m 100 feet The dual energy input can be connected to t...

Page 3: ...utdoor temperature is above the balance point high bP H the auxiliary heat is disabled see page 4 item 6 and only the heat pump can be used NOTE Balance points will not work if the AC144 03 outdoor te...

Page 4: ...point high 5 C to 30 C 23 F to 86 F 5 C 41 F Set the bP H value see section 4 2 7 Defrost point 10 C to 15 C 14 F to 59 F 10 C 50 F During defrost auxiliary heating is activated when the outside temp...

Page 5: ...ion Diagram New Installation TH146 P AC144 03 AC146 410 CT241 Humidifier Heat Pump Compressor Fault CT280 HP 2H1C Fan Auxiliary Heat Defrost Valve Dual Energy 16 22 AWG 16 22 AWG 16 22 AWG 16 22 AWG 1...

Page 6: ...Transformer Dual Energy AC144 03 AC146 410 CT241 RC845 Humidifier Auxiliary Heating System Heat Pump Compressor Defrost Fault Furnace Fan Limit CT280 HP 2H1C Yellow Red Green Reversing Valve 16 22 AWG...

Page 7: ...n Program clear Humidity setting Return Temperature adjustment mode selection Fan operating mode selection System operating mode selection Up Down buttons Indicator LEDs FAULT System fault EH Emergenc...

Page 8: ...days are selected they will all now have the same settings for period 2 To set the start time of a period first press Pgm until the period number P1 to P4 is displayed and the time display flashes The...

Page 9: ...rchase by the consumer If at any time during the warranty period the product is determined to be defective or malfunctions Aube shall repair or replace it at Aube s option If the product is defective...

Reviews: