Aube Technologies TH146-P-DE Installation Manual Download Page 7

TH146-P-DE

User’s Guide

Programmable Heat Pump Controller

TH146-P-DE 

      400-280-004-C                    11/29/06                    7/9

n

Press 

Clk

. The hour display flashes.

o

Set the hour using 

.

p

Press 

Clk

. The minute display flashes.

q

Set the minutes using 

.

r

Press 

Clk

. The day display flashes.

s

Set the day using 

.

t

Press   to return to the normal display.

n

Press 

Clk 

for 3 seconds to display the year.

o

Set the year using 

.

p

Press 

Clk

 to display the month.

q

Set the month using 

.

r

Press 

Clk

 to display the date.

s

Set the date using 

.

t

Press   to return to the normal display.

Press the 

Fan

 button to select the fan operating mode. 

In automatic mode, the fan runs only when heating or cooling is
activated.

In continuous mode, the fan runs continuously and the   sym-
bol is displayed. 

NOTE

: If the “smart fan” feature is enabled,

the fan will run only when heating or cooling will be activated
during unoccupied mode.

The controller normally displays the measured indoor temperature.
To view the setpoint, press one of the 

 buttons. The setpoint will

be displayed along with the   symbol for the next 5 seconds. 

Press 

Mode

 to place the system in one of the following modes: 

Time and day setting

Programming

Program day selection

Program clear

Humidity setting

Return

Temperature 
adjustment 
mode selection

Fan operating 
mode selection

System operating 
mode selection

Up/Down buttons

Indicator LEDs

FAULT

: System fault

EH

: Emergency heat mode

DE

: Dual-energy mode

Day

Clock

Indoor temperature

Outdoor temperature

Indoor humidity

Indicator LEDs

Backlight

During normal display, the screen
illuminates for 12 seconds when
any button is pressed. When the
controller is being configured, the
screen remains lit until it returns
to normal display.

5. General Setting

5.1

Clock and Day Setting

5.2

Date Setting

5.3

Fan Operating Mode

6. Temperature Setting

6.1

Display

6.2

System Operating Mode

HEAT

The system is in heating mode.

COOL

The system is in cooling mode.

AUTO

The system is in automatic changeover. (The system 
switches between heating mode and cooling mode to 
maintain the desired temperature.)

OFF

Both heating or cooling are off.

EHEAT

The system is in emergency heat mode. Only auxiliary 
heating is used when there is a call for heat.

Heating is On

Cooling is On

System operating mode

Fan operating mode 
(appears when the fan 
is in continuous mode, 
disappears when it is in 
automatic mode)

Temperature adjustment 
mode (appears when the 
controller is in automatic 
mode, disappears when it 
is in manual mode)

Auxiliary heating is On

Appears when the 
temperature setpoint 
is displayed

Indoor temperature

Summary of Contents for TH146-P-DE

Page 1: ...or air outlet or stagnant air behind a door Do not install the console on a wall hiding air ducts nor expose it to direct sunlight NOTE If this controller replaces an existing thermostat the wires tha...

Page 2: ...oller terminals PS and CS no polarity For more information refer to the instructions provided with the sen sor NOTE The maximum wire length is 30 m 100 feet The dual energy input can be connected to t...

Page 3: ...utdoor temperature is above the balance point high bP H the auxiliary heat is disabled see page 4 item 6 and only the heat pump can be used NOTE Balance points will not work if the AC144 03 outdoor te...

Page 4: ...point high 5 C to 30 C 23 F to 86 F 5 C 41 F Set the bP H value see section 4 2 7 Defrost point 10 C to 15 C 14 F to 59 F 10 C 50 F During defrost auxiliary heating is activated when the outside temp...

Page 5: ...ion Diagram New Installation TH146 P AC144 03 AC146 410 CT241 Humidifier Heat Pump Compressor Fault CT280 HP 2H1C Fan Auxiliary Heat Defrost Valve Dual Energy 16 22 AWG 16 22 AWG 16 22 AWG 16 22 AWG 1...

Page 6: ...Transformer Dual Energy AC144 03 AC146 410 CT241 RC845 Humidifier Auxiliary Heating System Heat Pump Compressor Defrost Fault Furnace Fan Limit CT280 HP 2H1C Yellow Red Green Reversing Valve 16 22 AWG...

Page 7: ...n Program clear Humidity setting Return Temperature adjustment mode selection Fan operating mode selection System operating mode selection Up Down buttons Indicator LEDs FAULT System fault EH Emergenc...

Page 8: ...days are selected they will all now have the same settings for period 2 To set the start time of a period first press Pgm until the period number P1 to P4 is displayed and the time display flashes The...

Page 9: ...rchase by the consumer If at any time during the warranty period the product is determined to be defective or malfunctions Aube shall repair or replace it at Aube s option If the product is defective...

Reviews: