Configuration Menu

Item

Parameters

Display

Options

Default

Description

1

Time format

12 Hr / 24 Hr

24 Hr

Select the time display format.

2

Early Start

On / OF

OF

On: Heating or cooling starts in advance (as determined by the 
controller) so that the desired temperature is attained at the set 
times. 
OF (Off): Heating or cooling starts at the set times.

NOTE

: Early Start applies for periods 1 and 3 (P1 and P3) only. 

When this feature is enabled, heating or cooling will start in 
advance of the set time for P1 and P3  but will start at the set 
time (not earlier) for P2 and P4.

3

Automatic daylight 

savings adjustment

OF / 1 / 2

OF

OF (Off): The normal time is used all year long.
1 : The controller switches to daylight savings time on the first 
Sunday of April and to normal time on the last Sunday of Octo-
ber.
2 : The controller switches to daylight savings time on the second 
Sunday of March and to normal time on the first Sunday of 
November.

4

Temperature scale

°C / °F

°C

Select the temperature display format.

5

Balance point low

-30°C to 10°C

(-22°F to 50°F)

-10°C

(14°F)

Set the bP L value (see section 4.2).

6

Balance point high

-5°C to 30°C

(23°F to 86°F)

5°C

(41°F)

Set the bP H value (see section 4.2).

7

Defrost point

-10°C to 15°C

(14°F to 59°F)

10°C

(50°F)

During defrost, auxiliary heating is activated when the outside 
temperature is below the defrost point (see section 4.3).

8

Installation type

Ad / nr

Ad

Set according to the type of heat pump installation (see section
4.4). 
Ad (add-on): Use this setting when the indoor coils are located
downstream of the auxiliary heat source. This is generally the
case for add-on installations.
nr (normal): Select this setting when the indoor coils are located
upstream of the auxiliary heat source. This is generally the case
for new installations.

9

Cycles per hour

2 to 6

4

Allows you to select the number of cycles per hour. It is recom-
mended to use the default setting except in exceptional cases.

10

“Smart fan”

On / OF

OF

On: “Smart fan” is On (see section 4.5).
OF: “Smart fan” is Off.

11

Interstage delay

5 to 90 min.

10 min.

Set the interstage delay (see section 4.6).

12

Humidifier 

operating mode

HE / Fn

HE

HE (heat): The humidifier can operate only when heating is acti-
vated.
Fn (fan): The humidifier can operate as long as the fan is run-
ning, whether heating is activated or not.

NOTE

: The humidifier is disabled when cooling is activated.

NOTE

: Only items 1 to 4 are available when the controller is placed in user mode (SW2 switch).

Summary of Contents for TH146-P-DE

Page 1: ...or air outlet or stagnant air behind a door Do not install the console on a wall hiding air ducts nor expose it to direct sunlight NOTE If this controller replaces an existing thermostat the wires tha...

Page 2: ...oller terminals PS and CS no polarity For more information refer to the instructions provided with the sen sor NOTE The maximum wire length is 30 m 100 feet The dual energy input can be connected to t...

Page 3: ...utdoor temperature is above the balance point high bP H the auxiliary heat is disabled see page 4 item 6 and only the heat pump can be used NOTE Balance points will not work if the AC144 03 outdoor te...

Page 4: ...point high 5 C to 30 C 23 F to 86 F 5 C 41 F Set the bP H value see section 4 2 7 Defrost point 10 C to 15 C 14 F to 59 F 10 C 50 F During defrost auxiliary heating is activated when the outside temp...

Page 5: ...ion Diagram New Installation TH146 P AC144 03 AC146 410 CT241 Humidifier Heat Pump Compressor Fault CT280 HP 2H1C Fan Auxiliary Heat Defrost Valve Dual Energy 16 22 AWG 16 22 AWG 16 22 AWG 16 22 AWG 1...

Page 6: ...Transformer Dual Energy AC144 03 AC146 410 CT241 RC845 Humidifier Auxiliary Heating System Heat Pump Compressor Defrost Fault Furnace Fan Limit CT280 HP 2H1C Yellow Red Green Reversing Valve 16 22 AWG...

Page 7: ...n Program clear Humidity setting Return Temperature adjustment mode selection Fan operating mode selection System operating mode selection Up Down buttons Indicator LEDs FAULT System fault EH Emergenc...

Page 8: ...days are selected they will all now have the same settings for period 2 To set the start time of a period first press Pgm until the period number P1 to P4 is displayed and the time display flashes The...

Page 9: ...rchase by the consumer If at any time during the warranty period the product is determined to be defective or malfunctions Aube shall repair or replace it at Aube s option If the product is defective...

Reviews: