CHAPTER 1: DEVICE OVERVIEW
1-2
VersAtive
®
Pro, DigiVu
®
II, DigiStream – 1RU Hardware Interface Manual
Table 1 .2a: Front Panel Controls and Indicators
Panel Label
Function
Description
UID
Button
Universal Identifi er: A switch that will turn on the adjacent “
U
” light.
U
Indicator LED
Blue
Universal Information LED: The Universal Information BLUE LED is used to indicate
fan failure, power failure, overheat condition, or to identify the unit within a large rack
installation. This may be activated by the IPMI or front panel button.
State Indication:
•
Fast Blinking Red (1 per sec) - Fan Failure
•
Solid Red - CPU Overheated
•
Slow Blinking Red (1 per 4 sec) - Power Failure
•
Solid Blue - Local UID Button Depressed
•
Blinking Blue - IPMI Activated UID
Note: Deactivating the UID LED must be performed in the same way it was activated.
(If the UID LED was activated via IPMI, you can only turn the LED off via IPMI and not
with the UID button.)
HDD
Indicator LED
Green
Indicates SSD/HDD drive activity when fl ashing.
PWR
Indicator LED
Green
Indicates power is being supplied to the system’s power supply units. This LED should
be illuminated when the system is operating.
RST
Recessed Button Used to reboot the encoder.
PWR
Recessed Button The main power switch is used to apply or remove power to the encoder. Activating this
switch effectively turns the encoder off but keeps standby power supplied to the system.
You must unplug the system before servicing. Press again to power up.
1 .3 Device Initial Confi guration
NOTE: Each individual Device must have default Management (eth0) port IP address changed
from 192.168.0.23 before connecting them to the Management Switch.
Each of the Devices are factory confi gured with identical eth0 Management Port IP addresses. It is important to understand
that the standard ATX Networks default IP address of 192.168.0.23 for management is assigned to all products. Before
connecting each management port to the management switch, the IP addresses must be re-confi gured.