CHAPTER 5: STARTUP
VersAtive
®
Pro, DigiVu
®
II, DigiStream – 1RU Hardware Interface Manual
5-1
STARTUP
5 . Startup
Each of the Device chassis are factory confi gured identically with the standard ATX Networks default IP address of 192.168.0.23
assigned to port eth0 (Management Port). Before connecting each Device to the management switch, the IP addresses must
be re-confi gured for your network.
NOTE: This equipment must have default eth0 port IP addresses changed from 192.168.0.23
before operation is initiated.
NOTE:
It is important to connect the eth1, eth2, eth3, eth4 & eth5 streaming ports to a
GbE
capable switch
or risk uncontrolled continuity errors as a connected 100 Base-T network may be
fl ooded.
5 .1 Chapter Contents
•
“Management Computer”
•
“Connecting to Your Computer”
5 .2 Management Computer
It is required that the Management Computer meet these minimum requirements.
•
Wired Ethernet network port.
•
Web browser for Management GUI on 192.168.0.23.
5 .3 Connecting to Your Computer
All Device rear panels have eth0 Management ports factory assigned IP address
192 .168 .0 .23
, Figure 5-1.
NOTE: Please refer to the Operation Manual for programming guidance.
eth0
MGMT
192.168.0.23
eth1
Streaming
eth2 eth3 eth4 eth5
IPMI
Streaming Ports
Figure 5-1: Rear Panel Management Port - 192.168.0.23