iii
ATTO Technology Inc. FibreBridge Installation and Operation Manual
CLI error messages
The following error messages may be returned by the Command line Interface
ERROR. Invalid Command. Type 'Help' for command list.
ERROR. Wrong/Missing Parameters
Usage: <usage string>
ERROR. Command Not Processed
CLI summary reference
A summary of the Command Line Interface commands, their defaults, and where you can find the specific
command. Commands which have no default values associated with them have a blank entry in that column of
the table.
Command
Default
Example
BridgeModel
get bridgemodel
BridgeName
“ “
set bridgename Omega6
ClearEventLog
cleareventlog
Date
set date 03/03/03
DumpConfiguration
dumpconfiguration
DumpEventLog
dumpeventlog
EthernetPort
enabled
set ethernetport mp2 enabled
EthernetSpeed
auto
set ethernetspeed 100
Exit
exit
FCConnMode
loop-ptp
set fcconnmode all ptp
FCDataRate
auto
get fcdatarate 1
FCPortErrors
get fcporterrors all
FCPortList
fcportlist
FCSFPInfo
get fcsfpinfo 2
FCWWName get
fcwwname
1
FirmwareRestart
firmwarerestart
FlashImages
flashimages
Help
help driveinfo
IdentifyBridge
disabled
set identifybridge enabled
Info
info
IPAddress
0.0.0.0
get ipaddress mp1
IPDHCP
enabled
set ipdhcp mp1 disabled
IPDNSServer
0.0.0.0
get ipdnsserver
IPGateway
0.0.0.0
set ipgateway mp1 200.10.22.3
IPSubnetMask
255.255.0.0
get ipsubnetmask mp1
Password
Password
set password
Ping
ping mp1 192.42.155.155