Technical parameters
Rated operating voltage
Product model
Rated power
Power fuses
Setting range of temperature
Multiple language for
user interface
Setting range of air volume
Timing time
Temperature unit
Monitor contrast
Monitor resolution
Quick function
User temperature
compensation
Heating power display
Hot air flow
Cooling function of
standby heater
Vacuum pressure of
vacuum pen
Alarm function
Heating element
exception detection
Password protection
function
Temperature sensor
exception detection
Temperature adjustment
step
Air volume adjustment
step
Rapid temperature / air
volume
Working conditions
Storage conditions
Dimension
AC 230V±10% 50hz (110v±10% 60hz, optional)
GT-8102
T 6.3A (230VAC) T 12A (110V AC)
1000W(Max)
100℃ ~ 480℃/ 212
℉
~ 896
℉
Support Chinese / English interface;
Chinese interface by default
25%~99%
10~900S
℃/
℉
; ℃ by default
10~100%
Three groups of rapid temperature
±50℃ /±90
℉
Five dynamic power bars
Available (Enabled by default)
120L(Max)
Supported
-80Kpa
Heating element removal detection; heating element open
circuit detection; heating element overheating detection
Available (Disabled by default)
Sensor open circuit detection
Long press and the temperature will be adjusted at a step
of 10 units; momentarily press, and the temperature will
be adjusted at one unit.
Long press and the air volume will be adjusted at a step
of two units; momentarily press, and the air volume will
be adjusted at one unit.
3 groups of temperature / air volume,
which can be called quickly
240x160 Dots(white letters on blue)
Temperature 0℃~40℃ Relative humidity<80%
Temperature -20℃~80℃ Relative humidity<80%
315(L)×252(W)×127(H)mm
Approximately 4kg
Weight
6