After editing the curve, select Exit, and save the curve.
Press “ ” on the machine panel and the curve will not be
saved.
Press “ ” on the machine panel to save the curve.
For example: select Edit curve 4, and it needs to press “MENU” key again to enter Edit curve 4
(the default is empty curve).
Add curve node
19
1
4
3
5
2
C
Profile 4
C
Edit Profile
Selet
Profile
Empty
Profile
4
Edit Profile4
C
Edit Profile
4
Step 1
Time -
Temp -
Air -
Empty
Profile
Exit
Step 5
Time -
Temp -
Air -
Exit
Step 5
Time -
Temp -
Air -
Exit
Delete curve node
1
4
3
5
2
C
Profile 4
Edit Profile
Save changes?
No
Yes
Step: Operational step during the operation of hot air handle
(at most nine steps).
Time: Time of current operational step during the operation of
hot air handle.The total time of all steps is 600S at most.
Temperature: Operating temperature during the operation of
hot air handle.(100-480℃; closed when the temperature is
lower than 100℃)。
Air volume: Air volume during the operation of hot air handle
(25-99).
Note: Next step can be set only after three parameters of time,
temperature and air volume are set.
Operational steps of adding node:
As shown in the left figure:
Add one node to the curve 4,
After the time, temperature and air volume are set in Step 5,
confirm and save it.
Note: The node can be only added after the final node, and
after a node is added, a node blinking cursor will appear.
Operational steps of deleting node:
As shown in the left figure:
Add one node from the curve 4,
Reduce the time to zero at Step 5, and the node 5 is deleted.