50
14.1.1
Feeder cycle time
sec 10
14.1.2
Maximum boiler output
kW 12
14.1.3
Average boiler output
kW 6
14.1.4
Minimum boiler output
kW 3
14.1.5
100% fan power
ot/min 2400
14.1.6
50% fan power
ot/min 1800
14.1.7
30% fan power
ot/min 1100
14.1.8
50% H2 hysteresis
°C 5
14.1.9
30% hysteresis H1
°C 3
14.1.10
Boiler hysteresis
°C 10
14.1.11
Control mode
FuzzyLogic
14.1.12
Room thermostat
0
14.2.1
Fuel dose
g 130
14.2.2
Ignition test time
sec 60
14.2.3
Warm-up time
sec 60
14.2.4
Ignition time
min 9
14.2.5
Burning time
min 2
14.2.6
Burner fan power at ignition
ot/min 1580
14.2.7
Flame detection
% 10
14.2.8
Ignition of the burner fan
ot/min 1100
14.2.9
Burner fan power after ignition
ot/min 1450
14.3.1
Burner fan power during cleaning
ot/min 2650
14.3.2
Exchanger cleaning - work
sec 10
14.3.3
Cleaning time before ignition
sec 15
14.3.4
Cleaning the burner at night
NO
14.3.5
Burner cleaning cycles
3
14.4.1
Burner fan power during burnout
ot/min 1800
14.4.2
Maximum burn-up time
min 15
14.4.3
Minimum burn - up time
min 3
14.5.1
Supervision time
0
14.5.2
Boiler output in the mode - SUPERVISION
kW 2
14.5.3
Work cycle time - SUPERVISION
sec 20
14.5.4
Burner fan power - SUPERVISION
ot/min 900
14.6.1
Minimum burner fan power
% 9
14.6.2
Maximum burner fan power
% 100
14.6.3
Minimum fan speed
ot/min 400
14.6.4
Maximum fan speed
ot/min 2850
14.6.5
Low fuel detection time
min 1
14.6.6
Min. flame value in case of lack of fuel
% 5
14.6.7
Fan factor (PID)
% 30
14.6.8
Integer time constant
10
14.7
Thermostat selection
OFF
14.8
Minimum boiler temperature
°C 60
14.9
Maximum boiler temperature
°C 80
14.10
Boiler cooling temperature
°C 88
14.11
Backup boiler
0