background image

9

June 2008

Harmony™ - Installation Manual

- blank page -

Summary of Contents for Harmony Slant Top

Page 1: ...www atronic com Atronic Harmony Slant Top Installation Manual Rev 1 4 June 2008 ...

Page 2: ...ibuted transmitted transcribed stored in a retrieval system or translated into any human or computer language in any form or by any means electronic mechanical magnetic manual or otherwise or disclosed to third parties without the express written permission obtained from a properly authorized official of Atronic DISCLAIMER Atronic makes no representation or warranties express or implied with respe...

Page 3: ...Instructions Machine Components Dimensions Technical Data Machine Installation Overview Inspection Positioning Mount Toplight Replace Shipping Locks Prepare Coin Acceptor Prepare Hopper Check Commboard Settings Apply Power Basic Setup Overview only Tests Technical Support Telephone Numbers 4 5 7 10 13 14 16 17 17 17 17 18 18 18 19 21 22 23 CONTENT ...

Page 4: ... and cabinet drawings Target Audience We address qualified technical personnel who are involved in installation setup and configuration of Atronic gaming machines With this user group we assume that they are basically familiar with gaming machines and casino related terminology Please read this document and the contained safety notes carefully before you start machine installation Included Softwar...

Page 5: ...l HST Operating C5 x x x STD Spare Parts Manual HST Parts Catalogue Linked Gaming Products Manual product Setup and Configuaration for a particular linked gaming product such as Mystery Magic Hot Link etc Peripherals Coin and bill acceptors hopper printer etc See folder Peripherals on the Atronic Service Manual CD Note All mentioned manuals can be found on a CD ROM titled Atronic Service Manual 20...

Page 6: ...6 June 2008 Harmony Installation Manual blank page ...

Page 7: ...e safe operation Caution High Voltage Power cable must be disconnected from the main power socket so that the machine is free from electrical current The power switch is intended for service purposes only Caution Moving Parts Make sure to disconnect the hopper when working on it Caution The machine must not be cleaned using a high pressure cleaner or a vapor jet and must not be installed or operat...

Page 8: ...propriate side of the cabinet Edge protection must be mounted once the knock out plate has been removed Only qualified service personnel should perform repairs Electronic assemblies should only be changed with the power switched off Use only original Atronic parts for replacement Atronic commboard and mainboard Danger of explosion if battery is incorrectly repla ced Check for correct polarity and ...

Page 9: ...9 June 2008 Harmony Installation Manual blank page ...

Page 10: ...er Arm Rest Audit Key Switch Jackpot Key Switch Maindoor Lock Mechanical Meters Coin Bowl Drop Door Drop Door Lock second lock optional second lock optional Topper Arch Deck Glass Ticket Printer optional Coin Entry Functional Button Panel Bill Entry Bill Decal Name Plate Bill Door Bill Door Lock Subwoofer second lock optional Card Reader optional Hopper Drawer ...

Page 11: ...Coin Geometry Coin Unit Coin Acceptor Bill Acceptor Coin Optics Cashbox Stackerbox Bill Door Switch Filterboard Power Logicbox Lock Service Button Reset Button Buttonboard Multimediaboard Cover Maindoor Switch Hopper Drawer Switch Power Switch Power Outlets Power Supply Hopper Audit Key Switch Jackpot Key Switch ...

Page 12: ...Installation Manual MACHINE COMPONENTS MACHINE COMPONENTS Logic Box Logicbox Switch Backplane Commboard Mainboard DVD ROM Drive Graphic Card VP11 Release Lever for Multimediaboard Cover Multimediaboard Multimediaboard Cover ...

Page 13: ...13 June 2008 Harmony Installation Manual 880mm 34 6 670mm 26 4 1188mm 46 8 1685mm 66 3 993mm 39 1 1850mm 71 9 DIMENSIONS DIMENSIONS Inchvaluesroundedtoonedecimalplace ...

Page 14: ...de approx 160 Watt 0 7A 230V Payout Mode approx 230 Watt 1A 230V Max Power approx 350 Watt Without internal power outlets Power Supply Secondary Voltage 24V 4 5A 12V 12A 12V 0 5A 5V 11A 3 3V 7A Fuses Power Supply T 8A 250V UL fuse Fuses Filterboard F2 12 V T 6 3A 250V UL fuse F3 24 V T 4A 250V UL fuse Environmental Specifications Operating Temperature 0 C 45 C 32 F 113 F Operating Humidity 0 to 85...

Page 15: ...15 June 2008 Harmony Installation Manual blank page ...

Page 16: ... configuration and check EPROMs for proper fitting Replace shipping locks with casino specific locks Install and connect accounting system Check that all internal and external connections are seated correctly Prepare coin acceptor and hopper Thread the power cable out of the machine Do not yet connect power to the machine Apply power to the machine Load paper into the printer optional Execute basi...

Page 17: ...red by warranty Positioning The machine should be standing on a level flat and stable floor Ensure there are no local sources of high temperatures or moisture Avoid direct sunlight shining on the glass surfaces Mount Toplight Connect the toplight and mount as illustrated To avoid damaging the toplight hold the toplight at its lower ring when you screw it into the topper bayonet catch Replace shipp...

Page 18: ...p box Switching threshold can be altered with an adjustment srew Fill the hopper with that amount of coins tokens at which you want the switch to be activated Adjust switching threshold with the adjustment screw that operates the high level switch Note See manuals Peripherals Hopper for details Check Commboard Settings optional Read the section Commboard DIP Switch Settings within the software man...

Page 19: ...z Switch the machine on and check that the machi ne initializes The LED s on the masterboard they indicate correct voltages should all be lit The po wer switch is located at the power supply left to the hopper Note The power up cycle will take some minutes because the machine checks installed hardware and security relevant circuits To operate the ma chine while the maindoor is open pull the maindo...

Page 20: ...20 June 2008 Harmony Installation Manual blank page ...

Page 21: ...d Clear This will clear all machine data statistics and set tings including progressive jackpot configurati on 3 Carry out the Initial Setup After a RAM Reset the machine automatically en ters the Initial Setup menu The Initial Setup al lows to configure all basic machine setting 4 Carry out Progressive Jackpot Configuration A PC or notebook with Atronic s Alink Config soft ware is connected to th...

Page 22: ...t Test coin diverter Coin Acceptor Coin Diverter Test bill acceptor Bill Acceptor Validator Test without Stacking Test hopper payout and switching times Hopper Pay out x coins Note Please refer to the document Manual HI Soft ware version relevant for a particular software version e g C5 1 x x for detailed information Note Make sure to have the bill door keys and the cashbox keys at hand when perfo...

Page 23: ...t one of the numbers below Technical Support Locations Atronic Germany International Headquarter 49 5741 273 720 Atronic Peru 51 161 832 00 Atronic United Kingdom 44 1727 855 966 Atronic Russia 7 495 7377 299 If technical assistance is required outside of normal business hours please contact the Atronic Technical Hotline number below Atronic Technical Hotline numbers For technical assistance in Eu...