19
June 2008
Harmony™ - Installation Manual
MACHINE INSTALLATION
Apply Power
• Punch out one of the perforated knock-out plates
in order to provide access for the power cable (fi-
gure a).
• Mount the enclosed edge protection (figure b).
• Check that the machine mains cable has not been
damaged during transit.
• Check that the supply socket is in good condition
and not showing any signs of overheating or da-
mage.
• Connect the power cable to a
grounded
power out-
let, that is rated for min. 3A / 230V at 50 Hz or
6A / 115V at 60 Hz.
• Switch the machine on and check that the machi-
ne initializes. The LED's on the masterboard (they
indicate correct voltages) should all be lit. The po-
wer switch is located at the power supply left to
the hopper.
Note
: The power up cycle will take some minutes,
because the machine checks installed hardware
and security relevant circuits. To operate the ma-
chine while the maindoor is open, pull the maindoor
switch (set it to closed position).
M
ACHINE
I
NSTALLATION
Power Switch
(a)
(b)
At this point the machine installation is finished. Proceed
with Basic Setup. (Initial Setup and Service Menu settings)
Please refer to the software manual for a particular software
version for details, e.g.
Manual HI Software (C5.x.x.x STD)
Summary of Contents for Harmony Slant Top
Page 1: ...www atronic com Atronic Harmony Slant Top Installation Manual Rev 1 4 June 2008 ...
Page 6: ...6 June 2008 Harmony Installation Manual blank page ...
Page 9: ...9 June 2008 Harmony Installation Manual blank page ...
Page 15: ...15 June 2008 Harmony Installation Manual blank page ...
Page 20: ...20 June 2008 Harmony Installation Manual blank page ...