Setup
2.7 Remote Volume Connection
A two way euro block terminal has been provided for the connection of a remote volume control.
A potentiometer needs to be wired to these two terminals.
**DO NOT LINK OR SHORT THESE TERMINALS**
A
1K
Ω
potentiometer is required for the remote volume to work correctly. The Altronics A 2280B shown below would be
suitable.
The maximum distance from the amplifier the potentiometer can be connected is 100 metres. Fig 2.7 shows a typical
connection.
Altronics A 2280B
(Wallplate fitted with 1K
Ω
Potentiometer)
Fig 2.7
DIP 5
DIP 4
24V DC IN
+_
PTT
(short to
activate)
Power Fail
(Contacts
close on
power fail)
Send
Return
Tape Out
Preamp Out
Link To Charge
Backup battery
ALERT - EVAC MODULE
Output Levels
Voice Chime Alert
Over
& Evac
EV
COM
CAN
CH
AL
Triggers
L
R
+ –
Rem. Vol
Connect
to 1K
Ω
Pot
24V DC
Switched
Output
Interface
Balanced Line
2
1
3
1 2
3
4 5
6
7 8
1
2
3
4
1KΩ Potentiometer