1.6 LED STATUS INDICATORS
There are two led’s on the front panel which indicate when power is available and if there is a fault.
The fault led will turn on under the following conditions.
Overtemp
When the amplifier reaches a dangerous temperature the unit will shutdown, preventing damage. If this occurs, check for
short circuits on the speaker line or objects blocking the amplifiers air vents.
1.7 PROTECT MODE
If the amplifier reaches a critical temperature or is over-driven it will shutdown.
The amplifier has been designed with an in built protection mode which will throttle the amplifer back to 50% output if it
nears the shutdown temperature.
If the Protect Mode is active the amplifier LCD will flash “ON” and “OFF” to highlight that there is a problem with the
amplifier. The fault condition will be displayed on the screen. (see section 1.?? for more details)
1.8 LCD STATUS INDICATORS
The LCD is used to offer more detailed information about the status of the amplifier.
The following elements can all be indicated on the display but may not be visible unless required.
• Signal presence
• Master Volume Level
• Amplifier Output level in dB
• Remote volume level
• Current Limit Condition
• Voltage Limit Condition
• Heatsink Temperature
• 230V AC Presence
• 24V DC Presence
• Alert/Evac Activation
Overview