- 10 -
Particular note should be taken if the appliance is being added to an
existing installation
.
NOTE
: It is important that adequately sized piping runs directly to the
connection joint on the appliance with as few tees and elbows as possible to
give maximum supply volume.
NOTE
: Ensure the regulator is converted to the correct gas type that the
appliance will operate on. The regulator outlet pressure is fixed
ex-factory for the gas type .
1.
Correctly locate the appliance into its final operating position and using
a spirit level, adjust the legs so that the unit is level and at the correct
height.
2.
Connect the gas supply to the appliance through the regulator. A
suitable jointing compound which resists the breakdown action of
propane must be used on every gas line connection, unless compression
fittings are used.
3.
Check all gas connections for leakages.
4.
Check that the gas operating pressure.
5.
Turn off the mains gas supply and bleed the gas out of the appliance gas
lines.
6.
Turn on the gas supply and the appliance.
Verify the operating pressure remains correct
5. Transport and Storage
In the process of transportation, handle carefully and keep upright to
prevent damage of the product packing. Wrapped equipment should not be
in open air for a long time, and shall be placed in a well-ventilated and
non-corrosive gases warehouse. When equipment needs temporary storage,
rainproof measures should be taken.
6. Installation and Debugging
Any erroneous installation, adjustment, refit, overhaul or
maintenance may cause property damage or personal injury. The work
shall be performed by authorized and licensed technicians, otherwise
the manufacturer has the right not to provide warranty service;
Only be installed in accordance with AS 5601/AG601, the local gas,
electricity and other relevant codes.
6.1
、
Unpacking and Installation
Summary of Contents for ATO-4B-F