A T O N
AH66T
INSTALLATION MANUAL
©
ATON 2010
|
All rights reserved
.
Page 63
System Power Control
Description: Turns the system OFF. Status can be queried.
Examples:
&AH66,SYSOFF<cr> Turns all zones OFF (SYSOFF).
&AH66,SYSOFF,?<cr> QUERIES (?) the POWER STATUS of the SYSTEM (SYSOFF).
Possible
QUERY responses are:*AH66,SYSOFF,0 or *AH66,SYSOFF,1, where 0=OFF and
1=ON.
Treble Level Control
Description: Adjusts Treble level in a zone. Status can be queried.
Examples:
&AH66,TRE,6,+<cr> INCREASES (+) the TREBLE (TRE)in ZONE SIX (6) by 1 dB.
*
&AH66,TRE,9,-<cr> DECREASES (-) the TREBLE (TRE) in ZONE NINE (9) by 1 dB.
*
&AH66,TRE,10,0<cr> Sets the TREBLE (TRE) in ZONE TEN (10) to FLAT (0).
*
&AH66,TRE,2,+,6<cr> Sets the TREBLE (TRE) in ZONE TWO (2) to PLUS (+) SIX dB (6).
&AH66,TRE,3,-,2<cr> Sets the TREBLE (TRE) in ZONE THREE (3) to MINUS (-)
TWO dB (2).
&AH66,TRE,5,?<cr> QUERIES (?) the TREBLE (TRE) setting of ZONE FIVE (5).
*
Example
QUERY responses are:*AH66,TRE,5,0 (ZONE FIVE-TREBLE is FLAT),
*AH66,TRE,2,+,3 (ZONE FIVE-TREBLE is PLUS 3),
*AH66,TRE,5,-,4 (ZONE FIVE-TREBLE is MINUS 4).
*When increasing or decreasing the TREBLE setting by 1 dB, setting TREBLE to 0 (flat),
or querying settings, Parameter 3 is not used.
Prefix
Command
Parameter 1
&AH66
SYSOFF
?
Prefix
Command
Parameter 1
Zone #
Parameter 2 Parameter 3*
+/- dBs
&AH66
TRE
1-12
+/-/0/?
1-12